24 / 59 page ![]() Bosch Sensortec | BMP388 Datasheet 24 | 59 Modifications reserved |Data subject to change without notice | Printed in Germany Document number: BST-BMP388-DS001-07 Revision_1.7_112020 3.7.5.2. FIFO full interrupt FIFO Full interrupt status is asserted when the full interrupt condition is satisfied, when the filling level of the FIFO number of unread bytes in the FIFO = fifo_length_1 & fifo_length_0 is equal or higher than 504. The status of the FIFO full interrupt can be read back through the ffull_int bit. Interrupt status is cleared by reading the ffull_int bit high ‘1’ when the FIFO filling level is lower than 504. The FIFO full interrupt is propagated to INT pad only when it is enabled by setting bit ffull_en=‘1’. Latching mode configuration bit int_latch selects whether the interrupt status or condition is propagated to the INT pad. Figure 9:FIFO full interrupt, non-latched, with reads from FIFO Figure 10: FIFO full interrupt, latched, with reads from FIFO 3.7.5.3. Data ready Data ready interrupt status int_status.drdy is asserted after a pressure and temperature measurement ends and conversion results are stored to the data registers and to the FIFO. The status of the interrupt can be read back through the drdy bit. The data ready interrupt is propagated to INT pad when it is enabled by setting drdy_en=‘1’. Interrupt status is cleared by reading drdy bit high ‘1’. Data ready INT pad contribution is cleared automatically 2.5 ms after the interrupt assertion in the non-latched mode (int_latch=’0’). Corner cases: • If data ready interrupt is changed from latched to non-latched mode (int_latched changed from ‘1’ to ‘0’) after the interrupt was already asserted; timer is not running and it is not starting during the ongoing measurement, self-clearing does not happen. Timer is starting when next data ready comes. • If data ready is changed to be propagated to INT pad (drdy_int changed from ‘0’ to ‘1’) after the interrupt was already asserted; data ready INT pad contribution remains ‘0’ until next data ready interrupt assertion. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |