11 / 59 page ![]() Bosch Sensortec | BMP388 Datasheet 11 | 59 Modifications reserved |Data subject to change without notice | Printed in Germany Document number: BST-BMP388-DS001-07 Revision_1.7_112020 3.2. Power management The BMP388 has two separate power supply pins • VDD is the main power supply for all internal analog and digital regulator blocks. • VDDIO is a separate power supply pin, used for the supply of the digital interface. VDD and VDDIO pins can be energized in any order. A power-on reset generator is built in which resets the logic circuitry and the register values after the power-on sequence. The slope for ramp up time must not be less than 10 ms. After powering up, the sensor settles in sleep mode (see section 3.3). Completion of the power-on-reset or soft reset is indicated by the bit por_detected[0]. The bit is cleared after reading. Holding any interface pin (SDI, SDO, SCK or CSB) at a logical high level when VDDIO is switched off can permanently damage the device due caused by excessive current flow through the ESD protection diodes. Table 4: mode settings Parameter Symbol Min. Max. Unit Test7 VDDA power-on rising edge Vpor_vdda 1.35 1.6 V T VDDA power-on hysteresis Vpor_hyst_vdda 75 mV T VDDD power-on rising edge Vpor_vddd 2.7 1.08 V Q VDDD power-on hysteresis Vpor_hyst_vddd 200 mV Q 3.3. Power modes The BMP388 offers three power modes: sleep mode, forced mode and normal mode. These can be selected using the mode[1:0] bits in control register “pwr_ctrl”. Table 5: mode settings mode[1:0] Mode 00 Sleep mode 01 and 10 Forced mode 11 Normal mode 3.3.1. Sleep mode Sleep mode is set by default after power on reset. In sleep mode, no measurements are performed and power consumption (IDDSL) is at a minimum. All registers are accessible; Chip-ID and compensation coefficients can be read. 3.3.2. Forced mode In forced mode, a single measurement is performed according to selected measurement and filter options. When the measurement is finished, the sensor returns to sleep mode and the measurement results can be obtained from the data registers. For a next measurement, forced mode needs to be selected again. Forced mode is recommended for applications which require low sampling rate or host-based synchronization. 7 T: directly or indirectly tested at 100% at room temperature, Q: tested at the initial qualification and if necessary |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |