14 / 21 page ![]() 14 SML2108 2053 2.2 11/07/00 SUMMIT MICROELECTRONICS, Inc. PRELIMINARY Start and Stop Conditions Both Data and Clock lines remain high when the bus is not busy. Data transfer between devices may be initiated with a Start condition only when SCL and SDA are high. A high- to-low transition of the Data line while the Clock line is high is defined as a Start condition. A low-to-high transition of the Data line while the Clock line is high is defined as a Stop condition. See Figure 9. Protocol The protocol defines any device that sends data onto the bus as a Transmitter, and any device that receives data as a Receiver. The device controlling data transmission is called the Master, and the controlled device is called the Slave. In all cases the Summit Microelectronic devices are slave devices, since they never initiate any data transfers. Acknowledge Data is always transferred in 8-Bit bytes. Acknowledge (ACK) is used to indicate a successful data transfer. The Transmitting device will release the bus after transmitting eight bits. During the ninth clock cycle the Receiver will pull the SDA line low to Acknowledge that it received the eight bits of data (See Figure 10). The termination of a Master Read sequence is indicated by a non-Acknowl- edge (NACK), where the Master will leave the Data line high. Figure 9. I2C Start and Stop Timing Figure 10. Acknowledge Timing In the case of a Read from a Summit part, when the last byte has been transferred to the Master, the Master will leave the Data line high for a NACK. This will cause the Summit part to stop sending data, and the Master will issue a Stop on the clock pulse following the NACK. In the case of a Write to a Summit part the Master will send a Stop on the clock pulse after the last Acknowledge. This will indicate to the Summit part that it should begin its internal non-volatile write cycle. Read and Write The first byte from a Master is always made up of a seven bit Slave address and the Read/Write bit. The R/W bit tells the Slave whether the Master is reading Data from the bus or writing Data to the bus (1 = read, 0 = write). The first four of the seven address bits are called the Device Type Identifier (DTI). The DTI for the SML2108 is 1010. The next three bits are not used in the SML2108 (See Figure 11). The SML2108 will issue an Acknowledge after recognizing a Start condition and its DTI. In the read mode the SML2108 transmits eight bits of data, then releases the SDA line, and monitors the line for an Acknowledge signal. If an Acknowledge is detected, and no Stop condition is generated by the Master, the SML2108 will continue to transmit data. If an Acknowl- edge is not detected (NACK) the SML2108 will terminate further data transmission. See Figure 12. Figure 11. Typical Master Address Byte Transmission 2053 Fig09 SCL SDA In START Condition STOP Condition SCL SDA Trans SDA Rec 1 2 3 8 9 ACK 2053 Fig10 SCL SDA 1 2 3 8 9 4 5 6 7 1 0 1 R/W 0 x x x ACK 2053 Fig11 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |