| поискавой системы для электроныых деталей |
|
SC2620 датащи(PDF) 15 Page - Semtech Corporation |
|
|
|||||||||||||||||||||||||||||
SC2620 датащи(HTML) 15 Page - Semtech Corporation |
|
15 / 26 page ![]() 15 2006 Semtech Corp. www.semtech.com SC2620 POWER MANAGEMENT Applications Information Since the inductor current charges C BST, the bootstrap circuit requires some minimum load current to get going. Figures 8(a) and 8(b) show the dependence of the minimum input voltage required to properly bootstrap a 5V and a 3.3V converters on the load current. Once started the bootstrap circuit is able to sustain itself down to zero load. Shutdown and Soft-Start Each regulating channel of the SC2620 has its own soft- start circuit. Pulling its soft-start pin below 0.8V with an open-collector NPN or an open-drain NMOS transistor turns off the corresponding regulator. The other regulator continues to operate. With one channel turned off, the internal bias circuit is kept alive. In the “Typical Characteristics”, the soft-start pin current is plotted against the soft-start voltage with V IN = 5V. When one of the soft- start pins is pulled low, 105µA flows out of that pin. Pulling both soft-start pins below 0.2V shuts off the internal bias circuit of the SC2620. The total V IN current decreases to 40µA. In shutdown either SS pin sources only 2µA. A fast charging circuit (enabled by the internal bias circuit), which charges the soft-start capacitor below 1V, causes the difference in the soft-start pin currents. If either SS pin is released in shutdown, the internal current source pulls up on the SS pin. When this SS voltage reaches 0.3V, the SC2620 turns on and the V IN quiescent current Figure 9(a). Normal Soft-start. Fast Charge Output must be at least 70% of its set voltage in this interval or the regulator will undergo shutdown and restart (hiccup). Hiccup Enabled 0.3V 1V 0 2V 2.4V Switching Starts VSS 1V 0.7V VFB 0 1V 1V 2V 0.3V 0 Switching Not Switching Switching Not Switching 0 0.7V 1V VFB VSS VCOMP Figure 9(b). Start-up Fails due to (i) Short Soft-start Duration or (ii) Output Overload or (iii) Output Short-circuited. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |