20 / 73 page ![]() HT46R46E/C46E/R47E/C47E/R48AE/C48AE/R49E Rev. 1.20 20 August 15, 2007 Write Operations There is only one write operation which is a byte write. · Byte Write A byte write operation allows a single byte of data to be written into the EEPROM. For this to happen, a start condition, device address and read/write bit must first be transmitted. Then after the usual acknowledge signal is received from the EEPROM, the required EEPROM internal address information where the data is to be written must be transmitted. In this case, as an address is being written to the EEPROM, the read/write bit should be low. After the 8-bit address has been transmitted in an MSB format, the EEPROM will respond with another acknowledge signal. At this point the internal counter is now pointing to the re- quested address. Now the 8-bits of data to be written, in an MSB format, can be transmitted to the EEPROM. When the last bit has been received the EEPROM will respond with the usual acknowledge signal, after which a STOP condition should be trans- mitted to the EEPROM. After the EEPROM receives the STOP condition it will enter its internal write cycle. The internal write cycle is fully controlled and timed by the EEPROM and when running, no other EEPROM operations can be executed. · Internal Write Cycle After a write operation is executed and when the EEPROM receives the final STOP condition at the end of the write operation, it will enter its internally controlled and timed internal write cycle. When the in- ternal write cycle is executing, no other operations can be carried out on the EEPROM. Before executing fur- ther operations on the EEPROM, therefore, a time de- lay must be provided, whose value should be equal to the maximum write cycle time, tWR, as specified in the EEPROM A.C. Characteristics table. However as only a maximum time is provided, a better method, using polling to determine when the write cycle has finished, can be used. To do this a START condition, followed by a device address and read/write bit low, is transmit- ted to the EEPROM. If the write cycle has completed the EEPROM will respond with an acknowledge sig- nal, which means the SDA line will be pulled low. If the write cycle has not completed then no acknowledge signal will be generated and the SDA line will remain high. D e v i c e a d d r e s s W o r d a d d r e s s D a t a S D A S t a r t A c k n o w l e d g e f r o m E E P R O M - - S D A p u l l e d l o w R / W l o w - - W r i t e 1 0 1 0 0 0 0 W S t o p Byte Write S e n d W r i t e C o m m a n d S e n d S t o p C o n d i t i o n t o I n i t i a t e I n t e r n a l W r i t e C y c l e S e n d S t a r t S e n d D e v i c e A d d r e s s R / W = 0 A c k n o w l e d g e R e c e i v e d N e x t O p e r a t i o n N o Y e s S D A = 0 I n t e r n a l w r i t e c y c l e s t i l l r u n n i n g Internal Write Cycle Busy Polling |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |