Back Button PM7367 Datasheet HTML 32Page - PMC-Sierra, Inc PM7367 Datasheet HTML 33Page - PMC-Sierra, Inc PM7367 Datasheet HTML 34Page - PMC-Sierra, Inc PM7367 Datasheet HTML 35Page - PMC-Sierra, Inc PM7367 Datasheet HTML 36Page - PMC-Sierra, Inc PM7367 Datasheet HTML 37Page - PMC-Sierra, Inc PM7367 Datasheet HTML 38Page - PMC-Sierra, Inc PM7367 Datasheet HTML 39Page - PMC-Sierra, Inc PM7367 Datasheet HTML 40Page - PMC-Sierra, Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 36 / 323 page
background image
PM7367 FREEDM-32P32
DATA SHEET
PMC-1991499
ISSUE 2
FRAME ENGINE AND DATA LINK MANAGER
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMER’S INTERNAL USE
22
Pin Name
Type
Pin
No.
Function
PERRB
I/O
L19
The active low parity error signal (PERRB)
indicates a parity error over the AD[31:0] and
C/BEB[3:0] buses. Parity error is signalled
when even parity calculations do not match the
PAR signal. PERRB is set low at the cycle
immediately following an offending PAR cycle.
PERRB is set high when no parity error is
detected.
PERRB is enabled by setting the PERREN bit in
the Control/Status register in the PCI
Configuration registers space. Regardless of
the setting of PERREN, parity errors are always
reported by the PERR bit in the Control/Status
register in the PCI Configuration registers
space.
PERRB is updated on the rising edge of
PCICLK.
SERRB
OD
Output
M20
The active low system error signal (SERRB)
indicates an address parity error. Address parity
errors are detected when the even parity
calculations during the address phase do not
match the PAR signal. When the FREEDM-
32P32 detects a system error, SERRB is set low
for one PCICLK period.
SERRB is enabled by setting the SERREN bit in
the Control/Status register in the PCI
Configuration registers space. Regardless of
the setting of SERREN, parity errors are always
reported by the SERR bit in the Control/Status
register in the PCI Configuration registers
space.
SERRB is an open drain output and is updated
on the rising edge of PCICLK.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com