| поискавой системы для электроныых деталей |
|
PS501 датащи(PDF) 36 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
PS501 датащи(HTML) 36 Page - Microchip Technology |
|
36 / 42 page ![]() PS501 DS21818C-page 36 2004 Microchip Technology Inc. TABLE 10-3: AC CHARACTERISTICS (TA = -20°C TO +85°C; VREG (INTERNAL) = +3.3V ± 10%) Symbol Characteristic Min Typ Max Units Condition fRC Internal RC Oscillator Frequency — 512.000 — kHz fAD Internal A/D Clock Frequency — fRC/16 — kHz tCONV A/D Conversion Measurement Time, n-bit + sign — 2n/fAD — ms TABLE 10-4: AC CHARACTERISTICS – SMBus (TA = -20°C TO +85°C; VREG (INTERNAL) = +3.3V ± 10%) Symbol Characteristic Min Typ Max Units Condition fSMB SMBus Clock Operating Frequency <1.0 — 100 kHz Slave mode fSMB-MAS SMBus Clock Operating Frequency 50 fRC/8 68 kHz Master mode (Note 1) tBUF Bus Free Time between START and STOP 4.7 — — µs tSHLD Bus Hold Time after Repeated START 4.0 — — µs tSU:STA Setup Time before Repeated START 4.7 — — µs tSU:STOP STOP Setup Time 4.0 — — µs tHLD Data Hold Time 300 — — µs tSETUP Data Setup Time 250 — — µs tTIMEOUT Clock Low Time-out Period 10 — 35 ms (Note 2) tLOW Clock Low Period 4.7 — — µs tHIGH Clock High Period 4.0 — 50 µs (Note 3) tLOW:SEXT Message Buffering Time — — 10 ms (Note 4) tLOW:MEXT Message Buffering Time — — 10 ms (Note 5) tF Clock/Data Fall Time — — 300 ns (Note 6) tR Clock/Data Rise Time — — 1000 ns (Note 6) Note 1: Used when broadcasting AlarmWarning, ChargingCurrent and/or ChargingVoltage values to either a SMBus Host or a SMBus Smart Battery Charger. This is only used when the PS501 becomes a SMBus master for these functions. The receiving (slave) device may slow the transfer frequency. See SMBus Tutorial in P4 User’s Guide for additional information. 2: The PS501 will time-out when the cumulative message time defined from Start-to-Ack, Ack-to-Ack or Ack-to-Stop exceeds the value of tTIMEOUT, min. of 25 ms. The PS501 will reset the communication no later than tTIMEOUT, max. of 35 ms. 3: tHIGH max. provides a simple method for devices to detect bus idle conditions. 4: tLOW:SEXT is the cumulative time a slave device is allowed to extend the clock cycles in one message from the initial start to the stop. 5: tLOW:MEXT is the cumulative time a master device is allowed to extend its clock cycles within each byte of a message as defined from Start-to-Ack, Ack-to-Ack or Ack-to-Stop. 6: Rise and fall time is defined as follows: tR = (VIL MAX -0.15) to (VIHMIN +0.15) tF = 0.9 VDD to (VIL MAX -0.15) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |