| поискавой системы для электроныых деталей |
|
PS501 датащи(PDF) 22 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
PS501 датащи(HTML) 22 Page - Microchip Technology |
|
22 / 42 page ![]() PS501 DS21818C-page 22 2004 Microchip Technology Inc. 8.1.12 AverageCurrent (0x0b) Returns a one-minute rolling average based on at least 60 samples of the current being supplied (or accepted) through the battery’s terminals (mA). 8.1.13 MaxError (0x0c) Returns the expected margin of error (%) in the State- Of-Charge calculation. For example, when MaxError returns 10% and RelativeStateOfCharge returns 50%, the RelativeStateOfCharge is actually between 50% and 60%. The MaxError of a battery is expected to increase until the Smart Battery identifies a condition that will give it higher confidence in its own accuracy. For example, when a Smart Battery senses that it has been fully charged from a fully discharged state, it may use that information to reset or partially reset MaxError. The Smart Battery can signal when MaxError has become too high by setting the CONDITION_FLAG bit in BatteryMode. 8.1.14 RelativeStateOfCharge (0x0d) Returns the predicted remaining battery capacity expressed as a percentage of FullChargeCapacity (%). 8.1.15 AbsoluteStateOfCharge (0x0e) Returns the predicted remaining battery capacity expressed as a percentage of DesignCapacity (%). Note that AbsoluteStateOfCharge can return values greater than 100%. 8.1.16 RemainingCapacity (0x0f) Returns the predicted remaining battery capacity. The RemainingCapacity value is expressed in either current (mAh) or power (10 mWh), depending on the setting of the BatteryMode’s CAPACITY_MODE bit. 8.1.17 FullChargeCapacity (0x10) Returns the predicted pack capacity when it is fully charged. It is based on either current or power, depending on the setting of the BatteryMode’s CAPACITY_MODE bit. 8.1.18 RunTimeToEmpty (0x11) Returns the predicted remaining battery life at the present rate of discharge (minutes). The RunTimeToEmpty value is calculated based on either current or power, depending on the setting of the BatteryMode’s CAPACITY_MODE bit. This is an impor- tant distinction because use of the wrong calculation mode may result in inaccurate return values. 8.1.19 AverageTimeToEmpty (0x12) Returns a one-minute rolling average of the predicted remaining battery life (minutes). The AverageTimeToEmpty value is calculated based on either current or power, depending on the setting of the BatteryMode’s CAPACITY_MODE bit. This is an impor- tant distinction because use of the wrong calculation mode may result in inaccurate return values. 8.1.20 AverageTimeToFull (0x13) Returns a one-minute rolling average of the predicted remaining time until the Smart Battery reaches full charge (minutes). 8.1.21 ChargingCurrent (0x14) Sets the maximum charging current for the Smart Charger to charge the battery. This can be written to the Smart Charger from the Smart Battery or requested by the Smart Charger from the battery. 8.1.22 ChargingVoltage (0x15) Sets the maximum charging voltage for the Smart Charger to charge the battery. This can be written to the Smart Charger from the Smart Battery or requested by the Smart Charger from the battery. 8.1.23 BatteryStatus (0x16) Returns the Smart Battery’s status word (flags). Some of the BatteryStatus flags, like REMAINING_CAPACITY_ALARM and REMAINING_TIME_ALARM, are calculated based on either current or power, depending on the setting of the BatteryMode’s CAPACITY_MODE bit. This is impor- tant because use of the wrong calculation mode may result in an inaccurate alarm. The BatteryStatus function is used by the power management system to get alarm and status bits, as well as error codes, from the Smart Battery. This is basically the same information returned by the SBData AlarmWarning function except that the AlarmWarning function sets the error code bits all high before sending the data. Also, information broadcasting is disabled in the PS501. Battery Status Bits: bit 15: OVER_CHARGED_ALARM bit 14: TERMINATE_CHARGE_ALARM bit 13: Reserved bit 12: OVER_TEMP_ALARM bit 11: TERMINATE_DISCHARGE_ALARM bit 10: Reserved bit 9: REMAINING_CAPACITY_ALARM bit 8: REMAINING_TIME_ALARM bit 7: INITIALIZED bit 6: DISCHARGING bit 5: FULLY_CHARGED bit 4: FULLY_DISCHARGED The Host system assumes responsibility for detecting and responding to Smart Battery alarms by reading the BatteryStatus to determine if any of the alarm bit flags are set. At a minimum, this requires the system to poll the Smart Battery BatteryStatus every 10 seconds at all times the SMBus is active. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |