| поискавой системы для электроныых деталей |
|
33793 датащи(PDF) 18 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
33793 датащи(HTML) 18 Page - Freescale Semiconductor, Inc |
|
18 / 27 page ![]() Analog Integrated Circuit Device Data 18 Freescale Semiconductor 33793 FUNCTIONAL DEVICE OPERATION DSI COMMANDS AND RESPONSES REQUEST ID COMMAND This command will cause the device ID information to be read from internal storage and returned to the master during the response to the next message. The command format is found in Table 18. REQUEST ID RESPONSE This response message is sent during the next message following a valid long-word Request ID command to the addressed device. The response format is found in Table 19. The high byte is omitted during the short-word response. No response is generated if the command address field was $0. CLEAR COMMAND This command will open the bus switch and reset all registers to the reset state. The command format is found in Table 20. No response is generated for the Clear command. READ/WRITE NVM COMMAND If the NV bit has been set by a previous Initialization command and the NVM has not been programmed previously, this command will permanently program the device’s one-time programmable address and return the programmed value during the next message time. Once programmed, this nonvolatile address is used to set the device address register on the next and all subsequent power-ups. If the device is not blank, this command will return the programmed value during the next message time. Programming the NVM address to $0 is allowed. This ensures that the device always acts as a dynamically A3 A2 A1 A0 0 0 0 0 L3 L2 L1 L0 DR3 DR2 DR1 DR0 X3 X2 X1 X0 Legend A[3:0] = Address bits. DR[3:0] = I/O enabled as outputs (1 = enabled as output). L[3:0] = Programmed values. X[3:0] = Cyclic Redundancy Check (CRC). The CRC as calculated by the slave. Table 17. I/O Control Response Format Table 18. Request ID Command Format Data Address Command CRC – – – – – – – – A3 A2 A1 A0 0 1 0 0 X3 X2 X1 X0 Legend A[3:0] = Address bits. The address of the selected device. An address value of “0000” is ignored by all devices. X[3:0] = Cyclic Redundancy Check (CRC). The CRC as calculated by the master. Table 19. Request ID Response Format Address Status Data CRC A3 A2 A1 A0 0 0 0 0 V2 V1 V0 0 0 0 1 1 X3 X2 X1 X0 Legend A[3:0] = Address bits. The slave address. V[2:0] = Device version number. The silicon version number of the device. For this device the device type is 00011 as indicated by the lowest bits. X[3:0] = Cyclic Redundancy Check (CRC). The CRC as calculated by the slave. Table 20. Clear Command Format Data Address Command CRC – – – – – – – – A3 A2 A1 A0 0 1 1 1 X3 X2 X1 X0 Legend A[3:0] = Address bits. The address of the selected device. An address value of “0000” clears all devices. X[3:0] = Cyclic Redundancy Check (CRC). The CRC as calculated by the master. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |