| поискавой системы для электроныых деталей |
|
33793 датащи(PDF) 16 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
33793 датащи(HTML) 16 Page - Freescale Semiconductor, Inc |
|
16 / 27 page ![]() Analog Integrated Circuit Device Data 16 Freescale Semiconductor 33793 FUNCTIONAL DEVICE OPERATION DSI COMMANDS AND RESPONSES INITIALIZATION RESPONSE This response message is sent during the next message following a valid Initialization command to the addressed device. The response is shown in Table 10. Because this is a long-word only command, the short-word response is invalid. REQUEST STATUS COMMAND This command will cause the addressed device to return the status of the NV, U, and BS bits and the logic levels of the I/O and LOGICOUT. The command format is found in Table 11. REQUEST STATUS RESPONSE This response message is sent during the next message following a valid Request Status command to the addressed device. The response format is found in Table 12. The high byte is omitted during the short-word response. No response is generated if the command address field was $0. REQUEST VALUE n COMMAND This command will cause the analog level at one of the four I/O lines to be measured and returned on the following command. The command format is found in Table 13. The analog input measured is defined in Table 14. Legend A[3:0] = Address bits. The slave address. BS = Bus Switch Position (1 = closed). G[1:0] = Group bits (unused). NV = Nonvolatile Memory Write. The value of the NV bit in the slave. PA[3:0] = Bus Address to set the device to. X[3:0] = Cyclic Redundancy Check (CRC). The CRC as calculated by the master. Table 9. Initialization Command Format Table 10. Initialization Response Format High Byte Low Byte CRC A3 A2 A1 A0 0 0 0 BF NV BS G1 G0 PA3 PA2 PA1 PA0 X3 X2 X1 X0 Legend A[3:0] = Address bits. The slave address. BF = Bus Fault. Bus out short to battery detected. BS = Bus Switch Position (1 = closed). G[1:0] = Group bits (unused). NV = Nonvolatile Memory Write. The value of the NV bit in the slave. PA[3:0] = Bus Address to set the device to. X[3:0] = Cyclic Redundancy Check (CRC). The CRC as calculated by the slave. Table 11. Request Status Command Format Data Address Command CRC – – – – – – – – A3 A2 A1 A0 0 0 0 1 X3 X2 X1 X0 Legend A[3:0] = Address bits. The address of the selected device. An address value of "0000" is ignored by all devices. X[3:0] = Cyclic Redundancy Check (CRC). The CRC as calculated by the master. Table 12. Request Status Response Format High Byte Low Byte CRC A3 A2 A1 A0 0 0 0 0 NV U LO BS IO3 IO2 IO1 IO0 X3 X2 X1 X0 Legend A[3:0] = Address bits. The slave address. BS = Bus Switch Position (1 = closed). LO = Logic out driven level. IO[3:0] = Values at logic I/Os. NV = Nonvolatile Memory Write. The value of the NV bit in the slave. U = Undervoltage indicated true by a “1”. X[3:0] = Cyclic Redundancy Check (CRC). The CRC as calculated by the slave. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |