15 / 27 page ![]() Analog Integrated Circuit Device Data Freescale Semiconductor 15 33793 FUNCTIONAL DEVICE OPERATION DSI COMMANDS AND RESPONSES DSI COMMANDS AND RESPONSES INITIALIZATION COMMAND The Initialization command must be sent to the 33793 before it may commence communications over the bus. The command may be used three ways. The first is to initialize a programmable address device. The second is the first step in assigning a pre-programmed address. The third is to initialize a pre-programmed device. For the first case this command is sent to address zero with the NV bit set to zero. The command will be received by the next daisy chain device with its bus switch open. Reception of this command will assign the device address and group number. For the second case the Initialization command is sent the same as the first except that the NV bit is set to one. Reception of the command will assign the device address and group number. A Read/Write NVM command then may be sent to complete the setting of a pre-programmed address. A pre-programmed device must be initialized by putting its address in both PA3:PA0 and A3:A0 fields. Once a device has received an initialization command, it will ignore further initialization commands unless it has received a Clear command or undergone a power-up reset. If BS = 1 and no faults are detected, initialization will cause the bus switch to close. The command format is found in Table 9. Table 8. Short-Word Response Summary Command Command Description Response 0000 Initialization Not Valid 0001 Request Status NV U LO BS IO3 IO2 IO1 IO0 0010 Request Value 0 B7 B6 B5 B4 B3 B2 B1 B0 0011 I/O Control Not Valid 0100 Request ID Information V2 V1 V0 0 0 0 1 1 0101 Request Value 1 B7 B6 B5 B4 B3 B2 B1 B0 0110 Request Value 2 B7 B6 B5 B4 B3 B2 B1 B0 0111 Clear No Response 1000 Request Value 3 B7 B6 B5 B4 B3 B2 B1 B0 1001 Read/Write NVM Not Valid 1010 Reserved 1011 Reserved 1100 Clear Logic Out NV U LO BS IO3 IO2 IO1 IO0 1101 Set Logic Out NV U LO BS IO3 IO2 IO1 IO0 1110 Reserved 1111 Reverse Initialization Not Valid Legend B[7:0] = 8-bit A/D value. BS = Status of the Bus Switch (1 = close). LO = Logic Out level at the Logic Out pin. IO[3:0] = Logic level of I/O. NV = Allows nonvolatile address programming if set to “1”. PA[3:0] = Bus Address to set the device to. U = Undervoltage Flag. V[2:0] = Version number. Table 9. Initialization Command Format Data Address Command CRC NV BS G1 G0 PA3 PA2 PA1 PA0 A3 A2 A1 A0 0 0 0 0 X3 X2 X1 X0 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |