| поискавой системы для электроныых деталей |
|
PCD5013 датащи(PDF) 39 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PCD5013 датащи(HTML) 39 Page - NXP Semiconductors |
|
39 / 76 page ![]() 1999 Apr 12 39 Philips Semiconductors Product specification FLEX ™ roaming decoder II PCD5013 8.6.7 CONFIGURATION OF ASSIGNED FRAMES AND PAGER COLLAPSE (ID = 20H TO 27H) The assigned frame and collapse value determine the frames in which the decoding device typically looks for messages (other system factors can cause the decoding device to look in other frames in addition to the typical frames). The PCD5013 must be configured explicitly to receive all required frames by setting the associated assigned frame (AF) bits. For each enabled CAPCODE these are the base frame and the associated frames implied by the pager collapse value. For example if the PCD5013 has one enabled address and it is assigned to base frame 3 with a collapse value of 4, the AF bits for frames 3, 19, 35, 51, 67, 83, 99 and 115 should be set and the AF bits for all other frames should be cleared. When the PCD5013 is configured for manual collapse mode by setting the MCM bit in the Roaming Control Packet, the PCD5013 does not apply the received system collapse to the AF bits. The host should set the AF bits for all frames that should be decoded on all channels. For example, if frames 0 and 64 should be decoded on one channel and frames 4, 36, 68, and 100 should be decoded on another channel, all six of the corresponding AF bits should be set. The host can then change the receiver’s carrier frequency after the PCD5013 decodes frames 0, 36, 64, and 100. There are 8 frame assignment packets each capable of assigning a range of 16 consecutive frame numbers. f: frame range, see Table 38 for location in the frame assignment packet and Table 36 for the AFs and values. The value determines which 16 frames out of a range of 128 correspond to the 16 AF bits in the packet. At least one of these bits must have been set when the PCD5013 is turned on by setting the ON bit in the control packet. Value after reset = 0. AF: assigned frame (Table 38). If a bit is set, the PCD5013 decodes the associated FLEX ™ frame and scans its contents for enabled addresses. Value after reset = 0. 8.6.8 CONFIGURATION OF ASSIGNED PHASE The assigned phase is required only for single-phase devices. It determines the phase (A, B, C, or D) in which the messages are received. For details of phase calculation see Section 8.6.5. For details of programming the assigned phase see Section 8.4.7. Table 36 Frame assignment ranges 8.6.9 OPERATOR MESSAGING ADDRESS ENABLE PACKET (ID = 04H) The operator messaging address enable packet is used to enable and disable the built-in FLEX ™ operator messaging addresses. Enabling and disabling operator messaging addresses does not affect on which frames the decoder IC decodes. To ensure that the correct frames are decoded, the host must modify the FF bits in the Control Packet or the AF bits in the Frame Assignment Packets. OAE: operator messaging address enable (Table 37). When a bit is set, the corresponding operator messaging address is enabled. When it is cleared, the corresponding operator messaging address is disabled. OAE0 to OAE15 corresponds to the hexadecimal operator messaging address values of 1F7810 through to 1F781F respectively. Value after reset = 0. f2 f1 f0 AF15 AF0 0 0 0 frame 127 frame 112 0 0 1 frame 111 frame 96 0 1 0 frame 95 frame 80 0 1 1 frame 79 frame 64 1 0 0 frame 63 frame 48 1 0 1 frame 47 frame 32 1 1 0 frame 31 frame 16 1 1 1 frame 15 frame 0 Table 37 Operator messaging address enable packet bit assignments BYTE BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 300000100 200000000 1 OAE15 OAE14 OAE13 OAE12 OAE11 OAE10 OAE9 OAE8 0 OAE7 OAE6 OAE5 OAE4 OAE3 OAE2 OAE1 OAE0 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |