| поискавой системы для электроныых деталей |
|
BT261 датащи(PDF) 21 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
BT261 датащи(HTML) 21 Page - List of Unclassifed Manufacturers |
|
21 / 56 page ![]() Brooktree® 15 CIRCUIT DESCRIPTION The Status Registers SR00 and SR05 Used in Automatic Phase L261_H Bt261 30 MHz Pixel Clock Monolithic CMOS HSYNC Line Lock Controller The Status Registers SR00 and SR05 Used in Automatic Phase Limiting Bits 0 and 5 of the status register can be used to debug phase-locked-loop operation of the Bt261. Phase-lock pixel-count bits CR27–CR24 define a pixel count used by the Bt261 to determine if the part is in “Lock.” The Bt261 compares the time dur- ing which the phase comparator is active (the PLL correction time) with the time defined in pixel count. If the compare time is less than phase-lock pixel count, the loop is considered locked and SR00 is not altered. If the compare time is greater than the phase-lock pixel count, SR00 is reset to zero. Previous to query, SR00 must be set to one by writing to command bit CR12. CR37–CR30 contains the phase-lock line count. This register determines the number of lines that must have a phase error less than that defined in the CR27–CR24 phase-lock pixel count for the system to be considered continuously locked. SR05 is reset to zero if there have been phase-lock line-count number of continuous lines with phase error less than that defined in the phase-lock pixel count. SR05 cannot be altered by the MPU. SR05 is set to one if SR00 is set to zero on any line (indicating a phase error greater than that defined in phase-lock pixel count). Bit 5 of the status register is used by the phase-limiting circuitry to determine if phase limiting should be enabled or disabled. If phase limiting is automatic, i.e., when phase limiting is enabled and lock is not overridden, (CR10 = CR22 = 1), SR05 determines whether phase limiting should be performed. SR05 is the lock control indicated in Figure 3a. The active period compared with the value in CR27–CR24 is output directly from the phase comparator. Because of this, all digital noise-gate and phase-limit operation is included when the phase error is compared with the phase-lock pix- el-count value. Therefore, the value in CR27–CR24 must be less than 500 ns in the typical case or 350 ns in the worst case commercial temperature range. This re- quirement ensures that a phase-limited line is not incorrectly interpreted as a locked line. SR05 can be used as a PLL debug tool. If the status register is addressed and the RD* pin of the Bt261 is held low, then SR05 will indicate the lock status. This bit will set low when lock is held for the number of lines defined in the phase-lock line count. When this condition is observed while the phase-comparator output is viewed through two vertical intervals, the Bt261 response relative to the loop per- formance can be studied. Lock should be indicated well before the next vertical in- terval (see Figure 6). Phase-limit enable must be deactivated during this evaluation (CR10 = 0); otherwise, phase limiting will affect the ability to monitor the loop-ac- quisition time. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |