| поискавой системы для электроныых деталей |
|
DSPIC30F датащи(PDF) 95 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
DSPIC30F датащи(HTML) 95 Page - Microchip Technology |
|
95 / 220 page ![]() 2004 Microchip Technology Inc. Preliminary DS70116C-page 93 dsPIC30F5011/5013 15.8 Slope Control The I2C standard requires slope control on the SDA and SCL signals for Fast mode (400 kHz). The control bit, DISSLW, enables the user to disable slew rate con- trol if desired. It is necessary to disable the slew rate control for 1 MHz mode. 15.9 IPMI Support The control bit, IPMIEN, enables the module to support Intelligent Peripheral Management Interface (IPMI). When this bit is set, the module accepts and acts upon all addresses. 15.10 General Call Address Support The general call address can address all devices. When this address is used, all devices should, in theory, respond with an Acknowledgement. The general call address is one of eight addresses reserved for specific purposes by the I2C protocol. It consists of all ‘0’s with R_W = 0. The general call address is recognized when the Gen- eral Call Enable (GCEN) bit is set (I2CCON<15> = 1). Following a Start bit detection, 8 bits are shifted into I2CRSR and the address is compared with I2CADD, and is also compared with the general call address which is fixed in hardware. If a general call address match occurs, the I2CRSR is transferred to the I2CRCV after the eighth clock, the RBF flag is set and on the falling edge of the ninth bit (ACK bit), the master event interrupt flag (MI2CIF) is set. When the interrupt is serviced, the source for the inter- rupt can be checked by reading the contents of the I2CRCV to determine if the address was device specific or a general call address. 15.11 I2C Master Support As a master device, six operations are supported: • Assert a Start condition on SDA and SCL. • Assert a RESTART condition on SDA and SCL. • Write to the I2CTRN register initiating transmission of data/address. • Generate a Stop condition on SDA and SCL. • Configure the I2C port to receive data. • Generate an ACK condition at the end of a received byte of data. 15.12 I2C Master Operation The master device generates all of the serial clock pulses and the Start and Stop conditions. A transfer is ended with a Stop condition or with a Repeated Start condition. Since the Repeated Start condition is also the beginning of the next serial transfer, the I2C bus will not be released. In Master Transmitter mode, serial data is output through SDA, while SCL outputs the serial clock. The first byte transmitted contains the slave address of the receiving device (7 bits) and the data direction bit. In this case, the data direction bit (R_W) is logic ‘0’. Serial data is transmitted 8 bits at a time. After each byte is transmitted, an ACK bit is received. Start and Stop con- ditions are output to indicate the beginning and the end of a serial transfer. In Master Receive mode, the first byte transmitted con- tains the slave address of the transmitting device (7 bits) and the data direction bit. In this case, the data direction bit (R_W) is logic ‘1’. Thus, the first byte trans- mitted is a 7-bit slave address, followed by a ‘1’ to indi- cate receive bit. Serial data is received via SDA while SCL outputs the serial clock. Serial data is received 8 bits at a time. After each byte is received, an ACK bit is transmitted. Start and Stop conditions indicate the beginning and end of transmission. 15.12.1 I2C MASTER TRANSMISSION Transmission of a data byte, a 7-bit address, or the sec- ond half of a 10-bit address is accomplished by simply writing a value to I2CTRN register. The user should only write to I2CTRN when the module is in a WAIT state. This action will set the Buffer Full Flag (TBF) and allow the baud rate generator to begin counting and start the next transmission. Each bit of address/data will be shifted out onto the SDA pin after the falling edge of SCL is asserted. The Transmit Status Flag, TRSTAT (I2CSTAT<14>), indicates that a master transmit is in progress. 15.12.2 I2C MASTER RECEPTION Master mode reception is enabled by programming the Receive Enable bit, RCEN (I2CCON<11>). The I2C module must be Idle before the RCEN bit is set, other- wise the RCEN bit will be disregarded. The baud rate generator begins counting and on each rollover, the state of the SCL pin ACK and data are shifted into the I2CRSR on the rising edge of each clock. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |