12 / 40 page ![]() UPD301A DS00002838B-page 12 2018-2019 Microchip Technology Inc. Port Control PRT_CTRL/OCS I/O2/OD2 When the UPD301A is in the Source Role, any external VBUS/VCONN/temperature faults may be wire-ORed on OCS to indicate a default has occurred, prompting the device’s firmware to make VBUS safe (open load switches, discharge VBUS, and enter error recovery). When the UPD301A is in the Source Role, this pin is a bi- directional signal indicating various faults to a load switch, DC/DC converter, DFP or hub. This pin is nominally config- ured as an output, sending faults to a load switch or DC/DC converter. However, if a different fault condition (e.g. over- voltage) is detected internally by the UPD301A, this pin is reconfigured as an open-drain output with an internal pull- down enabled and asserted low for a duration to allow detection by the hub’s PRT_ENx/OCSx_N input, and is then reconfigured back to an input. Note: For proper operation, a 100kOhm pull-up to +3.3V should be applied to this pin externally. Type-C Orientation ORIENTATION_N O2 This signal is used to indicate which CC pin is terminated by the attached device. When asserted CC = CC1, other- wise CC=CC2. Note: For proper operation, a 200kOhm pull-up to +3.3V should be applied to this pin externally. System Reset Input RESET_N_IN I Active low system reset input. This reset is used for reset of the UPD301A by a companion MCU. System Reset Output RESET_N_OUT O2 Active low system reset output. This pin must be connected to RESET_N_COM for proper operation. System Reset Common RESET_N_COM IS This pin must be connected to RESET_N_OUT for proper operation. No Connect NC - For proper operation, this pin must be left unconnected. Configuration Straps Power Delivery Power Select 0 Configuration Strap PDP_SEL0 I/O2 This multi-level configuration strap is sampled after system reset to specify a Power Delivery Power (PDP) which defines the voltages and currents to be used by the UPD301A Power Delivery Objects (PDOs). Refer to Section 3.3, "Configuration Straps" for additional information. Power Delivery Power Select 1 Configuration Strap PDP_SEL1 I/O2 For a two port system, this multi-level configuration strap is sampled after a system reset to specify a Power Delivery Power (PDP) which defines the voltages and currents to be used by the optional external UPD350 Power Delivery Objects (PDOs). Refer to Section 3.3, "Configuration Straps" for additional information. I2C Address Select Configuration Strap I2C_ADDR_SEL AIO This multi-level configuration signal is sampled after a sys- tem reset to select the device’s default I2C slave address. Refer to Section 3.3, "Configuration Straps" for additional information. TABLE 3-2: PIN DESCRIPTIONS (CONTINUED) Name Symbol Buffer Type Description |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |