| поискавой системы для электроныых деталей |
|
AS3682 датащи(PDF) 29 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS3682 датащи(HTML) 29 Page - ams AG |
|
29 / 43 page ![]() AS3682 austriamicrosystems Data Sheet Control of CURR2, CURR3, CURR4 in Normal Mode and Soft Flash Mode www.austriamicrosystems.com Revision 2.21 29 - 43 11.4 Control of CURR2, CURR3, CURR4 in Normal Mode and Soft Flash Mode CURR2, CURR3, and CURR4 are independent current sinks. The current value is determined by registers Current2 (page 21), Current3 (page 21), and Current4 (page 22). Any value other than zero will start the current sink. To stop the current, the register value must be set to zero. Note: Unused current sinks should be left open and any associated register values must be set to 0mA. Table 30. Current Sink2,3,4 Undervoltage Indication Registers Addr: 0F Curr_voltage_control This register indicates if the voltage at any current sink has dropped below a predefined value. If the charge pump is operating in automatic-mode (default), the contents of this register can be disregarded. The voltages at current sinks 1x are used for automatic mode selection of the charge pump. The voltages at current sinks 2, 3, and 4 can be optionally used for automatic mode selection of the charge pump (see register Curr234_ctrl (page 29)). Bit Bit Name Default Access Description 0 curr11_low_voltage N/A R See curr11_low_voltage (page 26). 1 curr12_low_voltage N/A R See curr12_low_voltage (page 26). 2 Curr13_low_voltage N/A R See curr12_low_voltage (page 26). 3 Curr2_low_voltage N/A R 0 = Normal operation. 1 = Undervoltage occurred. 4 Curr3_low_voltage N/A R 0 = Normal operation. 1 = Undervoltage occurred. 5 Curr4_low_voltage N/A R 0 = Normal operation. 1 = Undervoltage occurred. 7:6 cp_status N/A R See cp_status (page 30). Addr: 09 Curr234_ctrl This register defines wether the load of the current sink is connected to pin VBAT or to pin CP_OUT. If the load of the current sink is connected to CP_OUT, that current sink will contribute to the charge pump mode-selection algorithm. Bit Bit Name Default Access Description 0 Curr2_onCP 0R/W 0 = The output of the current sink will not be used for automatic mode selection of the charge pump. 1 = The output of the current sink is used for automatic mode selection of the charge pump. 1 Curr3_onCP 0R/W 0 = The output of the current sink will not be used for automatic mode selection of the charge pump. 1 = The output of the current sink is used for automatic mode selection of the charge pump. 2 Curr4_onCP 0R/W 0 = The output of the current sink will not be used for automatic mode selection of the charge pump. 1 = The output of the current sink is used for automatic mode selection of the charge pump. 3 Curr234_gpio0_ctrl 0R/W 0 = Curr2, Curr3, and Curr4 are switched on/off directly by registers Current2 (page 23), Current3 (page 23), and Current4 (page 23). 1 = Curr2, Curr3, Curr4 are switched on/off by pin GPIO0/P0 (set bit preview_ctrl (page 25) = 1 and bit Curr234_strobe_ctrl = 0. 6:4 N/A 7 Curr234_strobe_ctrl 0R/W 0 = Curr2, Curr3, and Curr4 are switched on/off directly by registers Current2 (page 23), Current3 (page 23), and Current4 (page 23). 1 = Curr2, Curr3, Curr4 are controlled by Strobe mode (enable at least one of curr11_on (page 24), curr12_on (page 24), or curr13_on (page 24). |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |