| поискавой системы для электроныых деталей |
|
AS3682 датащи(PDF) 26 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS3682 датащи(HTML) 26 Page - ams AG |
|
26 / 43 page ![]() AS3682 austriamicrosystems Data Sheet Timing Control of CURR11, CURR12, CURR13 in Normal Mode and Soft Flash Mode www.austriamicrosystems.com Revision 2.21 26 - 43 Addr: 05 Strobe_mode2 This register sets the strobe time in mode 2. Bit Bit Name Default Access Description 2:0 Mode2 111 R/W 000 = TS is equal to TSTROBE_SIGNAL if T_STROBE_SIGNAL. ≤ 100ms. 000 = TS is equal to 100ms is T_STROBE_SIGNAL ≥ 100ms. 001 = TS is equal to TSTROBE_SIGNAL if T_STROBE_SIGNAL ≤ 200ms. 001 = TS is equal to 200ms if T_STROBE_SIGNAL ≥ 200ms. 010 = TS is equal to TSTROBE_SIGNAL if T_STROBE_SIGNAL ≤ 300ms. 010 = TS is equal to 300ms if T_STROBE_SIGNAL ≥ 300ms. 011= TS is equal to TSTROBE_SIGNAL if T_STROBE_SIGNAL ≤ 400ms. 011 = TS is equal to 400ms if T_STROBE_SIGNAL ≥ 400ms. 100 = TS is equal to TSTROBE_SIGNAL if T_STROBE_SIGNAL ≤ 500ms. 100 = TS is equal to 500ms if T_STROBE_SIGNAL ≥ 500ms. 101 = TS is equal to TSTROBE_SIGNAL if T_STROBE_SIGNAL ≤ 600ms. 101 = TS is equal to 600ms if T_STROBE_SIGNAL ≥ 600ms. 110 = TS is equal to TSTROBE_SIGNAL if T_STROBE_SIGNAL ≤ 700ms. 110 = TS is equal to 700ms if T_STROBE_SIGNAL ≥ 700ms. 111 = TS is equal to TSTROBE_SIGNAL if T_STROBE_SIGNAL ≤ 800ms. 111 = TS is equal to 800ms if T_STROBE_SIGNAL ≥ 800ms. 7:3 N/A Table 29. Current Sink_1x Undervoltage Indication Register Addr: 0F Curr_voltage_control This register indicates if the voltage at any current sink has dropped below a predefined value. If the charge pump is operating in automatic-mode (default), the contents of this register can be disregarded. The voltages at current sinks 1x are used for automatic mode selection of the charge pump. The voltages at current sinks 2, 3, and 4 can be optionally used for automatic mode selection of the charge pump (see register Curr234_ctrl (page 29)). Bit Bit Name Default Access Description 0 curr11_low_voltage N/A R 0 = Normal operation. 1 = Undervoltage occurred. 1 curr12_low_voltage N/A R 0 = Normal operation. 1 = Undervoltage occurred. 2 curr13_low_voltage N/A R 0 = Normal operation. 1 = Undervoltage occurred. 3 Curr2_low_voltage N/A R See Curr2_low_voltage (page 29). 4 Curr3_low_voltage N/A R See Curr3_low_voltage (page 29). 5 Curr4_low_voltage N/A R See Curr4_low_voltage (page 29). 7:6 cp_status N/A R See cp_status (page 30). |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |