| поискавой системы для электроныых деталей |
|
L9945 датащи(PDF) 124 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9945 датащи(HTML) 124 Page - STMicroelectronics |
|
124 / 151 page ![]() Figure 29. FSM describing diagnostic priority NO 1 1 1 0 0 X 0 0 0 1 1 1 0 0 1 1 1 0 1 0 EN 0 0 Notes: GADG1003170942PS SPI READOUT EN NON EN NON STB/STG FAIL Legenda: Default state Transition without fault Transition with fault via SPI) also to control input (applies channel control the generic NON refers to en_OUT_xx bit EN refers to the default state events lead to SPI readout POR, NRES and turn OFF to output active OC failure leads EN NON EN NON VOL FAIL EN EN NON EN NON NON NON LVT FAIL NON VOL FAIL NON NON FAILURE OC NON FAILURE OL FAILURE STG/STB STG/STB NO FAILURE NO EN = 0 DIAG NO OC EN NON VOL FAIL Note: In case a diagnostic event occurs during SPI readout, such event is latched and provided with the next diagnostic request. 6.3 ON state diagnostics The following diagnostic codes can be set during the output ON state: • The diagnostic code corresponding to normal operation while in ON state is "No OC failure" (101); • The "No failure" (100) code will be reported only once, after an OFF->ON transition, assuming that "No OL/STG/STB failure" latch was set while in OFF state and "No OC failure" is detected; • The "OC failure" (001) or "OC pin failure" (000) codes will be reported in case of overcurrent detection. L9945 protects the external FET against overcurrent (OC) during the ON phase. The device features an analog comparator with a programmable overcurrent threshold. Sensing is performed measuring the voltage drop on an external element and comparing it to the programmed threshold. Such threshold can be compensated against battery and temperature variations for specific applications. 6.3.1 Behavior in case of OC detection If an OC event is detected, the output is actively shut off and the "OC failure" message is encoded in the diag_xx[2-0] bit. To prevent FET damage, in case the normal operation gate charge/discharge currents are low (1 mA or 5 mA), the device selects a higher shut off current among the ones available through GCC_config_xx. By programming the GCC_override_config, it is possible to select the entity of current increase in case of OC, as shown in the table below. These settings are in common between all channels. Table 37. Selection of fast shutdown currents in case of OC detection GCC_override_config IPU or IPD [mA] 0 1 → 5 5 → 20 L9945 ON state diagnostics DS12275 - Rev 8 page 124/151 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |