11 / 24 page ![]() SMS64 Preliminary Summit Microelectronics, Inc 2060 2.22 10/09/03 11 POWER SEQUENCING The SMS64 is a programmable controller for power supply sequencing. Up to six channels can be sequenced in any order with several delay options. In order for a power supply to be sequenced it must be enabled by a PUP output and monitored by the corresponding VM input. This channel must also be programmed to participate in the sequence and be assigned to a sequence position. If a channel is not programmed to participate in the sequence it should be assigned to the null sequence position (position 7) and the channel will act strictly as a voltage monitor. A sequence position is given to each channel as an order to the sequence. The sequence position assignments must begin at position 0 and must not skip positions. Also, multiple channels can be programmed into the same sequence position to enable more than one supply at a time. Note: If two or more channels with high voltage PUP outputs share the same sequence position their power-on delays must be either equal or differ by at least tSLEW (time it takes for the PUP output to slew from 0V to the level of VGG_CAP). Each channel selected for sequencing is given a power-on and power-off delay. The power-on delay is a delay from the VM input of one channel going out of fault to the PUP output of another channel going active. The power-off delay is the delay from the VM input of one channel turning off to the PUP output of another channel that is turning off. The power-on and power-off delay options are 25ms, 50ms, 100ms and 200ms. If the fast times option is selected in the configuration register, these delays are divided by 16 (1.5625ms, 3.125ms, 6.25ms and 12.5ms). Before the SMS64 begins the power-on sequencing the voltage monitors are monitoring the VCC inputs. The power-on sequencing will not begin until all of the VCC inputs that are selected as precursors to power-on sequencing are out of their fault conditions, the ‘precondition qualifiers’. Power-on sequencing can be initiated by toggling the PWR_ON/OFF pin from low to high or by writing to the power-on bit of the command register. For automatic start-up the PWR_ON/OFF can be floated as the device receives power. Either of these will initiate the power-on sequence as soon as the precursor conditions are met. During the power-on sequence power-off commands as well as activity on the PWR_ON/OFF pin is ignored. The power-on sequencing begins with the power- on delay time of the channel(s) in sequence position 0. Once this delay has timed out the PUP will go active. At this point the supply connected to the VM input will begin to turn on. When this supply reaches its programmed threshold (under-voltage) and the PUP output has reached the level of VGG_CAP (high voltage PUP outputs only) the sequence position counter will change to position 1 and the power-on delay timer for the channel(s) in sequence position 1 will begin. This will repeat until all channels that were programmed for sequencing have turned on and are not in fault conditions. Once sequencing is complete RST_B# will clear after tPRTO. Power-off sequencing can be initiated by a high to low transition on the PWR_ON/OFF pin, by writing to the power-off bit of the command register, or triggered off of a selected fault condition. The SMS64 can be configured to sequence the supplies off in the same order or reverse order of the power-on sequence. During the power-off sequence power-on commands as well as activity on the PWR_ON/OFF pin is ignored. The power-off sequencing begins with the power- off delay time of the channel(s) in the last sequence position of the power-on sequence (reverse order). Once this delay has timed out the PUP will turn off. At this point the supply connected to the VM input will begin to turn off. When this supply falls below 0.8V the sequence position counter will change to the next position and the power-off delay timer for the channel(s) in current sequence position will begin. This will repeat until all channels that were programmed for sequencing have turned off. At this point the voltage monitors will switch from the VM inputs to the VCC inputs to monitor for the precursor conditions to power-on sequencing. Note: With the OFF sensors disabled (configuration option) the SMS64 will immediately increment to the next sequence position instead of waiting until the VM inputs reach 0.8V. FORCED SHUTDOWN The forced shutdown function is always enabled. This function is used to immediately turn off all PUP outputs when there is not enough time to perform a power-off sequence. Forced shutdown can be initiated by pulling the FS# pin low, by writing to the forced shutdown bit of the command register, or triggered off of a selected fault condition. APPLICATIONS INFORMATION (CONTINUED) |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |