| поискавой системы для электроныых деталей |
|
LTC1968 датащи(PDF) 23 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC1968 датащи(HTML) 23 Page - Linear Technology |
|
23 / 28 page ![]() 23 LTC1968 1968f The trade-off here is that on the one hand, the DC error is input frequency dependent, so a calibration signal fre- quency high enough to make the DC error negligible should be used. On the other hand, as low a frequency as can be used is best to avoid attenuation of the calibrated AC signal, either from parasitic RC loading or insufficient op amp gain. For instance, with a 1kHz calibration signal, a 1MHz op amp will typically only have 60dB of open-loop gain, so it could attenuate the calibration signal a full 0.1%. AC-Only, 2 Point The next most significant error for AC-coupled applica- tions will be the effect of output offset voltage, noticeable at the bottom end of the input scale. This too can be calibrated out if two measurements are made, one with a full-scale sine wave input and a second with a sine wave input (of the same frequency) at 10% of full scale. The trade-off in selecting this second level is that it should be small enough that the gain error effect becomes small compared to the gain error effect at full scale, while on the other hand, not using so small an input that the input offset voltage becomes an issue. The calculations of the error terms for a 200mV full-scale case are: Gain = Reading at 200mV – Reading at 20mV 180mV Output Offset = Reading at 20mV Gain –20mV DC, 2 Point DC-based calibration is preferable in many cases because a DC voltage of known, good accuracy is easier to gener- ate than such an AC calibration voltage. The only down side is that the LTC1968 input offset voltage plays a role. It is therefore suggested that a DC-based calibration scheme check at least two points: ±full scale. Applying the –full-scale input can be done by physically inverting the voltage or by applying the same +full-scale input to the opposite LTC1968 input. For an otherwise AC-coupled application, only the gain term may be worth correcting for, but for DC-coupled applications, the input offset voltage can also be calcu- lated and corrected for. The calculations of the error terms for a 200mV full-scale case are: Gain = Reading at 200mV + Reading at – 200mV 400mV Input Offset = Reading at – 200mV – Reading at 200mV 2 •Gain Note: Calculation of and correction for input offset voltage are the only way in which the two LTC1968 inputs (IN1, IN2) are distinguishable from each other. The calculation above assumes the standard definition of offset; that a positive offset is the case of a positive voltage error inside the device that must be corrected by applying a like negative voltage outside. The offset is referred to which- ever pin is driven positive for the +full-scale reading. DC, 3 Point One more point is needed with a DC calibration scheme to determine output offset voltage: +10% of full scale. The calculation of the input offset is the same as for the 2-point calibration above, while the gain and output offset are calculated for a 200mV full-scale case as: Gain = Reading at 200mV – Reading at 20mV 180mV Output Offset = Reading at 200mV +Reading at – 200mV – 400mV • Gain 2 APPLICATIO S I FOR ATIO |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |