| поискавой системы для электроныых деталей |
|
BPD1002 датащи(PDF) 13 Page - Bel Fuse Inc. |
|
|
|||||||||||||||||||||||||||||
BPD1002 датащи(HTML) 13 Page - Bel Fuse Inc. |
|
13 / 15 page ![]() BCD.00617 Rev AB,16-Nov-2015 Page 13 of 15 MELCHER The Power Partners. Accessories Data Sheet Backplanes BPD, BPF for T Series • Double or reinforced insulation between input and output, based on 250 VAC • Operational insulation between output and earth • The use in a pollution degree 2 environment • Connecting the input to a primary circuit with a maximum transient rating of 2500 V (overvoltage class III based on a 110 V primary circuit, overvoltage class II based on a 230 V primary circuit). Troubleshooting See also: T Series converters data sheet Functional Features. • All T Series converters are operating, all Sys OK LEDs are OFF. – Sys In is not referenced to Vo– • 3-phase AC input, Y-configuration. One T unit indicates Error. – single T unit failure or – single T unit inhibit or – single phase mains failure • All System OK LEDs are OFF, all T units indicate Error. – mains failure or – all T units inhibited, e.g. battery test or less likely – all T units have a failure • The red Error LED of one of the T units is ON. – T unit with Error LED ON has an overtemperature, the output is automatically re-enabled when the temperature drops below the limit. • The red Error LED flickers. – overvoltage disturbance from the mains. • One of the T units has all LEDs OFF. – short circuit across output of a T unit. • All Sys OK LEDs ON, at one T unit the Uo OK LED is ON. The remaining T unit are below the threshold level of the power down signal with the LED Uo OK OFF. – a fuse on the back plane damaged, relevant T unit with Uo OK ON. • All LEDs at the T units are OFF, mains is apparent. – short circuit across the power bus • Single phase AC input. Only one T unit is in operation. – wire jumpers on mains input connector X1 not con- nected to L2/ L3 input terminals • All Sys Good and Uo OK LEDs are ON, no output power. – output not connected to the system • All T units are operating. One or several T units indicate Error with the Uo OK LEDs OFF although the bus voltage is present. – Dset not referenced to Vo+ Isolation The electric strength test is performed in the factory as routine test in accordance with IEC/EN 60950 and EN 50514. Important: The backplane must carry the safety covers, which prevent from touching conductive parts. Such covers are mounted on both sides of the printed circuit board and over the bus bars. Removing the protection covers will provoke danger of high voltage or high energy impact! Testing by applying AC voltages will result in high and dangerous leakage currents flowing through the Y-capacitors (see fig. Block diagram of back plane). Table 6: Isolation Characteristic Input to Input to Output to Unit earth output earth Electric Required according to 1.5 3.0 0.5 kVAC strength IEC/EN 60950 2.1 4.2 0.7 kV DC test voltage Actual factory test 1 s 2.8 4.2 1.4 AC test voltage equivalent 2.0 3.0 1.0 kVAC to actual factory test Insulation resistance at 500 VDC >300 >300 >300 M Ω |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |