11 / 15 page ![]() BCD.00617 Rev AB,16-Nov-2015 Page 11 of 15 MELCHER The Power Partners. Accessories Data Sheet Backplanes BPD, BPF for T Series Table 5: Pin allocation of the signal terminal strip X5 Pin no. Electrical determination Pin designation 1 Supply negative (return potential) Vo– 2 Sys good input of T unit no. 3 Sys In 3 3 Sys good input of T unit no. 2 Sys In 2 4 Sys good input of T unit no. 1 Sys In 1 5 Sys good output of T unit no. 3 Sys Out 3 6 Sys good output of T unit no. 2 Sys Out 2 7 Sys good output of T unit no. 1 Sys Out 1 8 Inhibit or Ucr of T unit no. 3 i3/Ucr 9 Inhibit or Ucr of T unit no. 2 i2/Ucr 10 Inhibit or Ucr of T unit no. 1 i3/Ucr 11 Power down of T unit no. 3 D3 12 Power down of T unit no. 2 D2 13 Power down of T unit no. 1 D1 14 Supply positive Vo+ The signal terminal strip X5 is provided with a matching fe- male connector at delivery. The jumper strip X3 is provided with 12 jumpers at delivery. The pin allocation of the jumper strip is described in fig. 7, (Jumper strip X3), signal meshing. Safety and Installation Instructions Transportation For transportation use standard packaging material of the Company. Racks fitted with back planes are not designed for transporta- tion with the T Series AC-DC converters fitted into the racks. Connector Pin Allocation The power output is provided via the two bus bars, the positive one designated Vo+, the negative one Vo–. The following pin allocation tables define the electrical potentials and the physical pin positions on the connectors of the back planes. Table 4: Pin allocation of the mains input connector X1 Pin no. Electrical determination Pin designation 1 Input phase 1 L1 2 Input phase 2 L2 3 Input phase 3 L3 4 Input neutral N 5 Protective earth 6 Protective earth Input connector X1 is provided with a matching male connec- tor at delivery. Standard configuration: Pins 1, 2 and 3 are interconnected (for single phase operation). Installation Instruction The BPD/BPF Series back planes are components, intended exclusively for inclusion within other equipment by an industrial assembly operation or by professional installers. Installation must strictly follow the national safety regulations in compliance with the enclosure, mounting, creepage, clearance, casualty, markings and segregation requirements of the end-use application. Caution: It is the responsibility of the the installer to define and apply a safety concept for the whole system which is provided with this back plane. The following are under the aspects which have to be considered: • Consult the T Series data sheet on our website before con- necting the system to the mains. • The necessity to provide a cover over the live parts at the mains input (hazardous voltage) or over the DC-bus bars (energy hazard), preventing accidental contact during in- stallation, start-up of a system or maintenance, depends on the final installation as well as on the applicable safety re- quirements. • Service should be carried out by qualified personnel only. • Fuses should be replaced with the same types only. • The earth terminal on the back plane must be connected to safety ground. • Back planes in 3-phase ( ∆) configuration are available on request. Modifications to the back plane in the field from Y to ∆-configuration (and vice versa) are not recommended. • The maximum nominal input voltage is 230 VAC +10%. Higher input voltages may damage the T Series converters as well as the back plane. • Empty spaces in a rack should be covered by a dummy front panel. Caution: Prior to handling, the back plane must be discon- nected from mains and from other sources (e.g. batteries). Check for hazardous voltages and hazardous energy before and after altering any connections. Hazardous energy levels may be present at the output terminals even after the mains input voltage has been disconnected from the unit. This is indicated by the red error LEDs of the T series AC-DC converters. It is the responsibility of the installer to prevent an unwanted short-circuit across the output of the back plane, of the battery and of each T series AC-DC converter. In case of a short circuit across the output of a T unit, all LEDs will be off, although the mains may be present. The back planes are intended for stationary applications. They shall be installed in 19’’ racks according to DIN 41494. Install the back planes vertically, the mains input connector X1 being on the right-hand side of the back plane (view from the back), and make sure that there is sufficient air flow available for convection cooling of the T Series converters. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |