BPD1002 датащи(PDF) 2 Page - Bel Fuse Inc. |
|
|
|||||||||||||||||||||||||||||
BPD1002 датащи(HTML) 2 Page - Bel Fuse Inc. |
|
2 / 15 page ![]() BCD.00617 Rev AB,16-Nov-2015 Page 2 of 15 MELCHER The Power Partners. Accessories Data Sheet Backplanes BPD, BPF for T Series Functional Description The back plane is divided into 3 sections, each one fitted with an H15 female connector for one T unit, with the mains input section and the DC output section separated from each other. The layout of the standard back planes gives the user the flexibility to operate the system either in single phase or in 3-phase (Y) configuration. Connection to the mains is achieved via the 6-pole connector (X1). With the wire jumpers B10/20/30 in Y-position (standard configuration) each T unit is connected between its defined input line and the neutral. (Changing of the configuration by the customer is not recommended.) An input filter, provided in the supply line to each T unit minimizes the conducted noise at the input of the system. The positive output of each T unit is separately fed to the common power bus and is decoupled depending upon the back plane type, either by a fuse (F11/21/31) or by a decoupling diode (D11/21/31). The fuses (cartridge type) are externally accessible from the frontside. The BPF versions are fitted with a common preload (R25). Additional output capacitors (up to 3 per output,10 mF each) further reduce the low frequency output ripple and provide enhanced hold-up time. All relevant monitoring signals as well as control signal inputs and outputs are accessible at the signal terminal strip (X5). The jumper strip (X3) allows system specific signals accord- ing to different jumper settings. An auxilliary circuit (protected by a fuse F1, rated T1A, 250 V, 5 × 20 mm) allows a relay to be directly driven for system specific control functions. Each T unit provides an individually adjustable power down signal enabling bus status monitoring at different voltage levels. The threshold values can be set at the soldering tabs Dset (R13/14, R23/24 and R33/34). Note: If a power system is operated with 3 T units per back- plane, connection to the mains in a 3-phase configuration (Y or D) will provide equal load distribution on the input lines. Fur- thermore the low frequency ripple at the output of the T units is compensated to zero as long as all 3 T units are in operation. Model Selection Table 1: Type survey AC Input Input filters 1 Output capacitors Preload Application 85...255 VAC (reduced 100 Hz 1 or 3 phase (Y) output ripple) 2 BPD1002 x – – Front-end, fitted with diodes BPD1003 x 90 mF – BPF1004x – x Battery charger, fitted with fuses BPF1007x 50 mF x BPF1006x 90 mF x 19” Rack, 3 U Rack for systems with up to 3 T units 1 See also: Electromagnetic Compatibility. 2 Please refer to: Dimensioning Example of a Battery Charger System in Single Phase Connection 3 Only for LT units and 120/208 VAC. See fig.: Mains input arrangement. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |