Back Button TLE8082ES Datasheet HTML 33Page - Infineon Technologies AG TLE8082ES Datasheet HTML 34Page - Infineon Technologies AG TLE8082ES Datasheet HTML 35Page - Infineon Technologies AG TLE8082ES Datasheet HTML 36Page - Infineon Technologies AG TLE8082ES Datasheet HTML 37Page - Infineon Technologies AG TLE8082ES Datasheet HTML 38Page - Infineon Technologies AG TLE8082ES Datasheet HTML 39Page - Infineon Technologies AG TLE8082ES Datasheet HTML 40Page - Infineon Technologies AG TLE8082ES Datasheet HTML 41Page - Infineon Technologies AG Next Button
Zoom Inzoom in Zoom Outzoom out
 37 / 61 page
background image
7.3.1
Diagnosis in OFF-state
All low-side output stages provide open load diagnosis in OFF-state.
All low-side output power stages provide a short to GND diagnosis in OFF-state.
A pull-up current source, a pull-down current source and two detection thresholds are implemented for each
output OFF-state diagnosis.
A short to GND in OFF-state is detected if the output voltage level is below the Diagnosis in off threshold
low for a time longer than the specified filter time (Diagnosis in off filter time OUT1 and OUT2, Diagnosis in
off filter time OUT3 and OUT4).
An open load in OFF-state is detected if the output voltage level is between the Diagnosis in off threshold
low and the Diagnosis in off threshold high for a time longer than specified filter time (Diagnosis in off filter
time OUT1 and OUT2, Diagnosis in off filter time OUT3 and OUT4).
In case of an OFF-state diagnosis detection condition, the respective diagnosis bit in register Diag1 is set. The
diagnosis bits are reset after a readout of register Diag1 if no fault condition is present.
VOUTx
Vth,off,high
Vth,off,low
ON
OFF
tfilx,off
Register Diag1
OXDIA
No failure
Short to
GND
Open load
Short to GND
(if Diag was
read)
Open load
No failure
(if Diag1 was read)
tfilx,off
tfilx,off
tfilx,off
tfilx,off
tfilx,off
Figure 9
Short circuit to GND and open load diagnostic function timings (overview only)
The pull current sources are implemented to define the output voltage level in case of an open load in between
the two thresholds.
IOUTn
0
Ipu,off min
VBAT
VOUTn
Normal operation
Open load
Short to
GND
Vth,off,high
Vth,off,low
Ipu,off max
Ipd,off max
Idpd,off min
Figure 10
Diagnosis current behavior over output voltage
TLE8082ES
Small engine management IC
Power stages
Datasheet
37
Rev. 1.0
2021-03-23



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com