36 / 61 page ![]() 7 Power stages 7.1 Outputs 1 to 3 - inductive load drivers The TLE8082ES implements 3 low-side switches. Output 1 to 3 are intended to drive inductive loads like injectors, valves or relays. The outputs contain a clamping circuit for freewheeling of inductive loads. The control of OUT1 can be configured to direct drive with input pin IN1 or SPI control. OUT2 and OUT3 can be configured to direct drive with input pin IN23 or SPI control. The output configuration can be determined in the configuration register. If the pin control is selected, a high level at input pins IN1 and IN23 switches on the respective output (see Figure 11). 7.2 Output 4 - O2 heater driver The low-side switch output 4 is intended to drive resistive loads like O2 heaters. The output contains a clamping circuit for freewheeling of inductive loads, too. The TLE8082ES provides a current feedback output. The provided sink current at pin CFB4 is proportional to the current of OUT4. If OUT4 is switched off, CFB4 is in high ohmic state. The output current at pin CFB4 can be calculated as follows. ICFB4=gCFB4·IOUT4 Equation 1 The control of OUT4 can be configured to direct drive with input pin IN4 or SPI control. If pin control is selected, a high level at input pin IN4 switches on OUT4 (see Figure 11). 7.3 Protection and diagnosis of low-side output stages All low-side output stages are protected against overcurrent. If the current through a power stage is above the Overcurrent detection threshold for a time longer than Overcurrent switch off filter time, an overcurrent is detected and the affected powerstage is switched off. Additionally, the according overcurrent bit in register Diag1 is set. The following conditions must be fulfilled to switch on the powerstages after an overcurrent event has occurred: • no overcurrent condition • readout of register Diag1 to reset the diagnosis bit • power stage switch on command (SPI switch-on command or positive edge at pin INx) All low-side output stages are protected against overtemperature. If the power stage temperature is above the OUTx overtemperature detection threshold for a time longer than OUTx overtemperature filter time, an overtemperature is detected and the affected powerstage is switched off. Additionally, the overtemperature bit in register Diag1 is set. An Overtemperature hysteresis avoids a premature switch on. The following conditions must be fulfilled to switch-on the powerstages after an overtemperature event has occurred: • no overtemperature condition • readout of register Diag1 to reset the diagnosis bit • switch-on command (SPI switch on command or positive edge at pin INx) The OUT3 output switching status (ON/OFF) is detected by Diagnosis in off threshold high. The status bit O3Stat in register Diag0 is "1" with an output voltage below the threshold. TLE8082ES Small engine management IC Power stages Datasheet 36 Rev. 1.0 2021-03-23 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |