71 / 131 page ![]() BALSW Open Diagnostics The BALSW open diagnostic (BALSWDIAG[2:0] = 0b010) verifies that each enabled balancing switch is conducting (not open) as follows: ● Configures acquisition for bipolar mode (for measur- ing voltages near zero) automatically ● Configures acquisition for ALTMUX path automati- cally ● Configures acquisition to measure switch voltages for those switches enabled by BALSWEN automatically ● Host initiates acquisition ● Compares measurement to the threshold value BALLOWTHR and BALHIGHTHR (Table 36) auto- matically ● If outside the threshold, set the corresponding flag in ALRTBALSW automatically Set the thresholds by taking into account the minimum and maximum RSW of the switch itself as specified in the Electrical Characteristics table and the balancing current for the application. See Table 35 for BALSW Short-Diagnostic Auto- configuration, Table 36 for BALSW Diagnostics. See Table 37 for BALSW Open-Diagnostic Autoconfguration and Figure 44 for BALSW Open Diagnostics. Even/Odd Sense Wire Open Diagnostics If enabled, the sense-wire open diagnostic modes detect if a cell-sense wire is disconnected as follows: ● Closes nonadjacent switches (even or odd automatically) ● Configures acquisition to use ALTMUX path automatically ● Host waits 100µs for settling and then initiates the acquisition ● Compares the result to the BALHIGHTHR and BALLOWTHR registers automatically ● If outside thresholds, sets flags in ALRTBALSW automatically See Figure 45 for Cell Sense-Wire Open Diagnostics. Table 35. BALSW Short Diagnostic Autoconfiguration Table 36. BALSW Diagnostics Table 37. BALSW Open-Diagnostic Autoconfiguration CONFIGURATION BITS AUTOMATIC SETTING PURPOSE MEASUREEN[14:12] 0b000 Disable AUXIN and VBLKP measurements BALSWEN[11:0] 000h Disable all balancing switches DIAGCFG.ALTMUXSEL 1 Enable ALTMUX measurement path BALSW VSWn FAULT INDICATED? POSSIBLE FAULT CONDITION On > V(BALHIGHTHR) Yes Switch open circuit, or overcurrent > V(BALLOWTHR) No None < V(BALHIGHTHR) < V(BALLOWTHR) Yes Path open circuit, or short circuit Off > V(BALSHRTTHR) No None < V(BALSHRTTHR) Yes Short circuit, or leakage current CONFIGURATION BITS AUTOMATIC SETTING PURPOSE MEASUREEN[14:12] 0b000 Disable AUXINn and VBLKP measurements MEASUREEN[11:0] BALSWEN[11:0] Measure only active switch positions DIAGCFG.ALTMUXSEL 1 Enable ALTMUX measurement path SCANCTRL.POLARITY 1 Enable bipolar mode MAX17843 12-Channel, High-Voltage Smart Sensor Data-Acquisition Interface www.maximintegrated.com Maxim Integrated │ 71 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |