63 / 131 page ![]() READBLOCK Command The READBLOCK command returns an 18-byte read from the specified register for a block size of 1 in the addressed device only. If the register address is not valid for the device, it returns zero for any invalid addresses. If the device address is not valid, the command is ignored. The command sequences for a block size of 1 and for a block size of 2 are shown in Table 32 and Table 33, respectively. The command packet is forwarded up the daisy-chain until it reaches the addressed device. The addressed device overwrites the received fill bytes with the two bytes of register data (from a single device) and forwards the packet to the next device. The alive-counter byte is only incremented by the addressed device. A Manchester error immediately switches the data propagation from read mode to write (pass-through) mode, ensuring that the Manchester error is propagated through the daisy-chain and back to the host. Table 32. READBLOCK Sequencing for Block Size = 1 Table 33. READBLOCK Sequencing for Block Size = 2 *If alive-counter mode is enabled. *If alive-counter mode is enabled. HOST TX DEVICE RXL DEVICE TXU HOST RX Preamble Preamble Preamble Preamble {BS[4:0], 3b110} {BS[4:0], 3b110} {BS[4:0], 3b110} {BS[4:0], 3b110} [DEVICE ADDR] [DEVICE ADDR] [DEVICE ADDR] [DEVICE ADDR] [REG ADDR] [REG ADDR] [REG ADDR] [REG ADDR] [DC] [DC] [DATA LSB] [DATA LSB] [PEC] [PEC] [DATA MSB] [DATA MSB] [ALIVE]* [ALIVE]* [DC] [DC] [FD(1) C2h] [FD(1) C2h] [PEC] [PEC] [FD(1) D3h] [FD(1) D3h] [ALIVE]* [ALIVE]* Stop Stop Stop Stop 18 characters 18 characters 18 characters 18 characters HOST TX DEVICE RXL DEVICE TXU HOST RX Preamble Preamble Preamble Preamble {BS[4:0], 3b110} {BS[4:0], 3b110} {BS[4:0], 3b110} {BS[4:0], 3b110} [DEVICE ADDR] [DEVICE ADDR] [DEVICE ADDR] [DEVICE ADDR] [REG ADDR] [REG ADDR] [REG ADDR] [REG ADDR] [DC] [DC] [DATA0 LSB] [DATA0 LSB] [PEC] [PEC] [DATA0 MSB] [DATA0 MSB] [ALIVE]* [ALIVE]* [DATA1 LSB] [DATA1 LSB] [FD(1) C2h] [FD(1) C2h] [DATA1 MSB] [DATA1 MSB] [FD(1) D3h] [FD(1) D3h] [DC] [DC] [FD(1) C2h] [FD(1) C2h] [PEC] [PEC] [FD(1) D3h] [FD(1) D3h] [ALIVE]* [ALIVE]* Stop Stop Stop Stop 22 characters 22 characters 22 characters 22 characters MAX17843 12-Channel, High-Voltage Smart Sensor Data-Acquisition Interface www.maximintegrated.com Maxim Integrated │ 63 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |