| поискавой системы для электроныых деталей |
|
INA239 датащи(PDF) 17 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
INA239 датащи(HTML) 17 Page - Texas Instruments |
|
17 / 44 page ![]() • Alert polarity — Allows the device to invert the active state of the ALERT pin. Note that the ALERT pin is an open-drain output that must be pulled-up by a resistor. The ALERT pin is active-low by default and can be configured for active high function using the APOL control bit. Other diagnostic functions that are not reported by the ALERT pin but are available by reading the DIAG_ALRT register: • Math overflow — Indicated by the MATHOF bit, reports when an arithmetic operation has caused an internal register overflow. • Memory status — Indicated by the MEMSTAT bit, monitors the health of the device non-volatile trim memory. This bit should always read '1' when the device is operating properly. When the ALERT pin is configured to report the ADC conversion complete event, the ALERT pin becomes a multipurpose reporting output. Figure 7-6 shows an example where the device reports ADC conversion complete events while the INA239 device is subject to shunt over voltage (over current) event, bus under voltage event, over temperature event and over power-limit event. Shunt Voltage Temperature Bus Voltage ALERT (ALATCH = 0) (APOL = 0) (CNVR = 1) Power Shunt Over Voltage Threshold Bus Under Voltage Threshold Over Temp Threshold Power Over Limit Threshold BUV SET SOV SET BUV CLEAR SOV & BUV SET SOV CLEAR BUV & OT SET BUV & OT & OP SET - No diag. error - Conversion Complete Reported Figure 7-6. Multi-Alert Configuration 7.4 Device Functional Modes 7.4.1 Shutdown Mode In addition to the two conversion modes (continuous and triggered), the device also has a shutdown mode (selected by the MODE bits in ADC_CONFIG register) that reduces the quiescent current to less than 5 µA and turns off current into the device inputs, reducing the impact of supply drain when the device is not being used. The registers of the device can be written to and read from while the device is in shutdown mode. The device remains in shutdown mode until another triggered conversion command or continuous conversion command is received. The device can be triggered to perform conversions while in shutdown mode. When a conversion is triggered, the ADC will start conversion; once conversion completes the device will return to the shutdown state. Note that the shutdown current is specified with an inactive communications bus. Active clock and data activity will increase the current consumption as a function of the bus frequency as shown in Figure 6-23. 7.4.2 Power-On Reset Power-on reset (POR) is asserted when VS drops below 1.26V (typical) at which all of the registers are reset to their default values. A manual device reset can be initiated by setting the RST bit in the CONFIG register. The www.ti.com INA239 SLYS027 – JANUARY 2021 Copyright © 2021 Texas Instruments Incorporated Submit Document Feedback 17 Product Folder Links: INA239 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |