| поискавой системы для электроныых деталей |
|
HM8563 датащи(PDF) 12 Page - Shenzhen Huazhimei Semiconductor Co., Ltd |
|
|
|||||||||||||||||||||||||||||
HM8563 датащи(HTML) 12 Page - Shenzhen Huazhimei Semiconductor Co., Ltd |
|
12 / 22 page ![]() • 11 • 00 4096 01 64 10 1 11 1/60 Table 27 Timer countdown value register bits description 0FH Symbol Description b7~b0 <timer countdown value> countdown value n, the counter’s period is “”n/ fCLK” 2.8 EXT_CLK test mode A test mode is available which allows for on-board testing. In this mode it is possible to set up test conditions and control the operation of the RTC. The test mode is entered by setting bit TEST1 in the Control/Status1 register. The CLKOUT pin then becomes an input. The test mode replaces the internal 64 Hz signal with the signal that is applied to the CLKOUT pin. Every 64 positive edges applied to CLKOUT will then generate an increment of one second. The signal applied to the CLKOUT pin should have a minimum pulse width of 300 ns and a minimum period of 1000 ns. The internal 64 Hz clock, now sourced from CLKOUT, is divided down to 1 Hz by a 26 divide chain called a pre-scaler. The pre-scaler can be set into a known state by using the STOP bit. When the STOP bit is set, the pre-scaler is reset to 0. STOP must be cleared before the pre-scaler can operate again. From a STOP condition, the first 1 s increment will take place after 32 positive edges on CLKOUT. Thereafter, every 64 positive edges will cause a 1 s increment. Remark: Entry into EXT_CLK test mode is not synchronized to the internal 64 Hz clock. When entering the test mode, no assumption as to the state of the pre-scaler can be made. You can operate in the following steps: 1. Enter the EXT_CLK test mode; set bit 7 of Control/Status 1 register (TEST = 1) 2. Set bit 5 of Control/Status 1 register (STOP = 1) 3. Clear bit 5 of Control/Status 1 register (STOP = 0) 4. Set time registers (Seconds, Minutes, Hours, Days, Weekdays, Months/Century and Years) to desired value 5. Apply 32 clock pulses to CLKOUT 6. Read time registers to see the first change 7. Apply 64 clock pulses to CLKOUT 8. Read time registers to see the second change. Repeat steps 7 and 8 for additional increments if necessary. 2.9 Power-On Reset override mode The POR duration is directly related to the crystal oscillator start-up time. Due to the long HM8563 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |