| поискавой системы для электроныых деталей |
|
ZXLD1370EST16TC датащи(PDF) 30 Page - Diodes Incorporated |
|
|
|||||||||||||||||||||||||||||
ZXLD1370EST16TC датащи(HTML) 30 Page - Diodes Incorporated |
|
30 / 40 page ![]() ZXLD1370 Document number: DS32165 Rev. 6 - 2 30 of 40 www.diodes.com December 2016 © Diodes Incorporated ZXLD1370 Application Information (Cont.) FLAG/STATUS Outputs The FLAG/STATUS outputs provide a warning of extreme operating or fault conditions. FLAG is an open-drain logic output, which is normally off, but switches low to indicate that a warning, or fault condition exists. STATUS is a DAC output, which is normally high (4.5V), but switches to a lower voltage to indicate the nature of the warning/fault. Conditions monitored, the method of detection and the nominal STATUS output voltage are given in the following table: Table 2 Warning/Fault Condition Severity (Note 17) Monitored Parameters FLAG Nominal STATUS Voltage Normal Operation — — H 4.5 Supply Undervoltage 1 VAUX<5.6V L 4.5 2 VIN<5.6V L 3.6 Output Current Out of Regulation (Note 18) 2 VSHP outside normal voltage range L 3.6 Driver Stalled with Switch ‘On’, or ‘Off’ (Note 19) 2 tON, or tOFF>100µs L 3.6 Device Temperature Above Maximum Recommended Operating Value 3 TJ>+125°C L 1.8 Sense Resistor Current IRS Above Specified Maximum 4 VSENSE>0.32V L 0.9 Notes: 17. Severity 1 denotes lowest severity. 18. This warning will be indicated if the output power demand is higher than the available input power; the loop may not be able to maintain regulation. 19. This warning will be indicated if the gate pin stays at the same level for greater than 100µs (e.g., the output transistor cannot pass enough current to reach the upper switching threshold). VREF 0V 0A Normal Operations SEVERITY 4.5V 3.6V 2.7V 1.8V 0.9V VAUX UVLO - VIN UVLO - STALL - OUT of REG Over Temperature Over Current 0 1 2 3 4 Figure 35 Status Levels In the event of more than one fault/warning condition occurring, the higher severity condition will take precedence. E.g., ‘Excessive Coil Current’ and ‘Out of Regulation’ occurring together will produce an output of 0.9V on the STATUS pin. If VADJ>1.7V, VSENSE may be greater than the excess coil current threshold in normal operation and an error will be reported. Hence, STATUS and FLAG are only guaranteed for VADJ<=VREF. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |