| поискавой системы для электроныых деталей |
|
LTC2876 датащи(PDF) 23 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC2876 датащи(HTML) 23 Page - Linear Technology |
|
23 / 32 page ![]() LTC2876/LTC2877 23 28767fa For more information www.linear.com/LTC2876 5 6 3 8 1 2 4 7 9 1 2 3 5 5 4 1 4 3 2 28767 F16 M12 PLUG M12 SOCKET 9-PIN D-SUB Figure 17. Connector Pin Allocations applicaTions inForMaTion The D-sub connector is specified for use up to 12Mbps. Inductors are often built into the cable connectors to reduce unwanted ringing and reflections at data rates above1.5Mbits/s.Cableconnectorsarealsoavailablewith termination resistors that can be switched in/out. Table 3. Pin Designation For D-Sub and M12 Connectors. (Connections in Bold are Mandatory) PIN NUMBER CONNECTION 9-PIN D-Sub M12 1, Case Thread Cable Shield 2 GND for 24V Supply 3 4 PB (B – Red Wire) 4 CNTR-P (Repeater Direction Control) 5 3 GND for Bus Termination 6 1 VCC (+5V) for Bus Termination 7 +24V Supply 8 2 PA (A – Green Wire) 9 CNTR-N (Repeater Direction Control) 5 Not Used OPERATION IN RS485 AND RS422 SYSTEMS The LTC2876 and LTC2877 are completely compatible with standard RS485 and RS422 networks. In these in- stallations, the PB pin should be treated as the A pin for compatibility with most RS485 transceivers. Likewise, the PA pin should be matched up with the B signal in RS485. Further discussion about this can be found in section “Bus Pins PA and PB Naming Convention.” Twisted pair cables with characteristic impedance of 120Ω or 100Ω can be used. Shielded cable is recommended for the highest electromagnetic compatibility (EMC), but unshielded cable like CAT-5e works well. Untwisted pair cables (UTP) should be avoided. Both ends of a cable should be terminated differentially with resistors that match the cable’s impedance, as illustrated in Figure 10. Sometimes bus biasing resistors are used for non- PROFIBUS RS485 installations to introduce a high level (IDLE state) on the bus when nothing is driving it. An example of such a network is shown in Figure 181. Here the three resistors (620Ω, 130Ω, and 620Ω) replace the single 120Ω differential resistor in one location only. MAXIMUM PROFIBUS CABLE LENGTH The following table gives the maximum cable segment lengths at PROFIBUS baud rates, as specified in IEC 61158-2: Table 2. PROFIBUS Maximum Cable Length BAUD RATE (kbits/s) MAX. SEGMENT LENGTH (m) 9.6 1200 19.2 1200 45.45 1200 93.75 1200 187.5 1000 500 400 1500 200 3000 100 6000 100 12000 100 CONNECTORS The PROFIBUS standard only specifies the use of a 9-pin D-sub connector for stations and cables. A commonly used alternative is the 5-pin “B-coded” M12 circular con- nectors (IEC 947-5-2). In all cases, the female side of the connector is located in the station, while the cable uses the male end. Connector diagrams are shown in Figure 17 and pin designations are shown in Table 3. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |