| поискавой системы для электроныых деталей |
|
LTC2876 датащи(PDF) 22 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC2876 датащи(HTML) 22 Page - Linear Technology |
|
22 / 32 page ![]() LTC2876/LTC2877 22 28767fa For more information www.linear.com/LTC2876 applicaTions inForMaTion BUS PINS PA & PB NAMING CONVENTION PROFIBUScommunicateswithRS485signalingthrougha differential signal interface. These wires are labeled A and B. The PROFIBUS standard specifies that the bus wire B takes on a positive value with respect to bus wire A when no station is transmitting data (during the idle periods). However, the polarity convention of most RS485 devices uses the opposite convention. That is, with no transmis- sion on the bus, the receiver reports a logic value that would result if A were higher than B—in this case a high on RO. From a practical standpoint, this means that if a general RS485 transceiver is connected to a PROFIBUS network, the transceiver’s A pin must connect to the B wire and the B pin connect to the A wire. Certainly this can be confusing! Since the LTC2876/LTC2877 was designed specifically for PROFIBUS applications, the pin naming convention was made to match the PROFIBUS specification. To avoid confusion with other RS485 transceivers, the prefix “P” was added, meaning “PROFIBUS.” If driver and receiver are enabled, a high level on DI, will drive the bus lines so that PB is higher than PA and the receiver will report a high level on RO. In PROFIBUS installations, connect PB to the B wire (red) and PA to the A wire (green). For non-PROFIBUS RS485 applications,thePBpinshouldbeconnectedtotheAsignal and PA pin should be connect to the B signal to match the convention of most other RS485 devices. PROFIBUS CABLES It is recommended that PROFIBUS installations use cable designed for PROFIBUS applications. Typically, Type A cable and termination is used. This is a shielded twisted pair with the following properties: Table 1. PROFIBUS Type-A Cable Properties PROPERTY VALUE Impedance 135Ω to 165Ω Capacitance < 30pF/m Loop Resistance < 110Ω/km Conductor Area ≥ 0.34mm2 Color of Sheath (Non-IS) Violet Color of Inner Conductor A Green Color of Inner Conductor B Red The three resistors that make up the termination network should be placed at both ends of the bus and must be powered during operation. If there are multiple nodes communicating on the bus, only the nodes at the ends should be terminated. The cable shield helps to improve electromagnetic com- patibility (EMC). It is recommended to ground both ends of the shield, through the case of the connector, to the chassis of the connected station. In applications where ground potential differences exist between stations, for example long distance transmission between buildings, the shield should be grounded only at one end of the cable. If the potential difference exceeds several volts, galvanic isolation is recommended at one or more of the con- nectedstations.Inthiscase,considerusingtheLTM®2892 µModuleisolator(see3500VRMSIsolatedPROFIBUSNode with Termination on the last page). If the shield cannot be grounded through the connector case, pin 1 of the D-sub connector can be used as an alternative, although the added inductance makes this sub-optimal. In such a case, it is better to bare the cable shield at an appropriate point and ground it with a short cable or clamp to the metallic structure of the station. Unshielded cable can be used in PROFIBUS installations if there is no severe electromagnetic interference (EMI). Do not use cables that are untwisted pairs. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |