| поискавой системы для электроныых деталей |
|
MP8869SGL датащи(PDF) 32 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP8869SGL датащи(HTML) 32 Page - Monolithic Power Systems |
|
32 / 39 page ![]() MP8869S – 18V, 12A, SYNCHRONOUS STEP-DOWN CONVERTER MP8869S Rev. 1.03 www.MonolithicPower.com 32 1/18/2018 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2018 MPS. All Rights Reserved. APPLICATION INFORMATION Setting the Output Voltage in a FB Control Loop The MP8869S can be controlled by the FB loop. The output voltage can be set by the external resistor dividers. The FB loop reference voltage is a default value (0.72V) and can be programmed by the I2C. The MP8869S’s output voltage must be below the absolute OVP threshold (typically 6.5V). The FB loop network is shown in Figure 11. FB R2 R1 VOUT Rt Figure 11: FB Loop Network Calculate R1 and R2 with Equation (4): OUT R1 R2 V 1 0.72V (4) Table 6 lists the recommended feedback resistors value for common output voltages. Table 6: Resistor Selection for Common Output Voltages (8) VOUT (V) R1 (kΩ) R2 (kΩ) Rt( kΩ) L(μH) 1.0 80.6 205 10 1.5 1.2 80.6 121 10 1.5 1.5 80.6 74.4 10 1.5 1.8 80.6 53.6 10 1.5 2.5 80.6 32.4 10 2.2 3.3 80.6 22.6 10 2.2 5 80.6 13.7 10 3.3 NOTE: 8) The recommended parameters are based on a 12V input voltage and 22µFx4 output capacitor. Different input voltage and output capacitor values may affect the selection of R1 and R2 . For other components’ parameters, please refer to the Typical Application Circuits on page 36 to page 38. Output Voltage Dynamic Scale The output voltage dynamic scaling can be done only via the I2C. Refer to Figure 11 and follow the steps below. 1) Write GO_BIT (Reg01[6]) to 1. 2) Write Reg00 to set the reference voltage by feedback reference (Reg00 [6:0]) simultaneously. When the command is finished, GO_BIT auto-resets to 0 to prevent false operation of the VOUT scaling. Repeat the above two steps if the output voltage must be changed to a different voltage. Voltage scaling start Write Reg01[6] “GO_BIT”=1 Write Reg00 (“Vref”code) Voltage scaling is done Figure 12: Output Voltage Dynamic Scale Flow Chart Selecting the Inductor Use a 0.47µH to 5µH inductor with a DC current rating at least 25% higher than the maximum load current for most applications. For the highest efficiency, use an inductor with a DC resistance l ess than 5mΩ. For most designs, the inductance value can be derived from Equation (5): OUT IN OUT 1 IN L OSC V (V V ) L V I f (5) Where ∆IL is the inductor ripple current. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |