| поискавой системы для электроныых деталей |
|
AM29PDL128G80 датащи(PDF) 26 Page - SPANSION |
|
|
|||||||||||||||||||||||||||||
AM29PDL128G80 датащи(HTML) 26 Page - SPANSION |
|
26 / 69 page ![]() July 29, 2002 Am29PDL128G 25 P R E L I M I NARY PPB lock bit once again will lock the PPBs, and the device operates normally again. Note: to achieve the best protection, it’s recommended to execute the PPB lock bit set command early in the boot code, and protect the boot code by holding WP# = V IL. Table 9. Sector Protection Schemes Table 9 contains all possible combinations of the DYB- DYB, PPB, and PPB lock relating to the status of the sector. In summary, if the PPB is set, and the PPB lock is set, the sector is protected and the protection can not be removed until the next power cycle clears the PPB lock. If the PPB is cleared, the sector can be dynami- cally locked or unlocked. The DYB then controls whether or not the sector is protected or unprotected. If the user attempts to program or erase a protected sector, the device ignores the command and returns to read mode. A program command to a protected sector enables status polling for approximately 1 µs before the device returns to read mode without having modi- fied the contents of the protected sector. An erase command to a protected sector enables status polling for approximately 50 µs after which the device returns to read mode without having erased the protected sec- tor. The programming of the DYB, PPB, and PPB lock for a giv en s e c t or c an be v e ri f i ed by writing a DYB/PPB/PPB lock verify command to the device. Persistent Sector Protection Mode Locking Bit Like the password mode locking bit, a Persistent Sec- tor Protection mode locking bit exists to guarantee that the device remain in software sector protection. Once set, the Persistent Sector Protection locking bit pre- vents programming of the password protection mode locking bit. This guarantees that a hacker could not place the device in password protection mode. Password Protection Mode The Password Sector Protection Mode method allows an even higher level of security than the Persistent Sector Protection Mode. There are two main differ- ences between the Persistent Sector Protection and the Password Sector Protection Mode: s When the device is first powered on, or comes out of a reset cycle, the PPB Lock bit set to the locked state, rather than cleared to the unlocked state. s The only means to clear the PPB Lock bit is by writ- ing a unique 64-bit Password to the device. The Password Sector Protection method is otherwise identical to the Persistent Sector Protection method. A 64-bit password is the only additional tool utilized in this method. The password is stored in the first eight bytes of the SecSi Sector. Once the Password Mode Locking Bit is set, the password is permanently set with no means to read, program, or erase it. The password is used to clear the PPB Lock bit. The Password Unlock com- mand must be written to the flash, along with a pass- word. The flash device internally compares the given password with the pre-programmed password. If they match, the PPB Lock bit is cleared, and the PPBs can be altered. If they do not match, the flash device does nothing. There is a built-in 2 µs delay for each “pass- word check.” This delay is intended to thwart any ef- f o rt s t o ru n a pr og ra m t h at tr ie s a l l p o s s i ble combinations in order to crack the password. Because the password occupies the first eight bytes of the SecSi Sector, the password must be programmed before either the password protection mode is se- lected or the SecSi Sector protection bit is pro- grammed (to use both the SecSi Sector and Password Protection at the same time). See Utilizing Password and SecSi Sector Concurrently for more information. Password and Password Mode Locking Bit In order to select the Password sector protection scheme, the customer must first program the pass- word. AMD recommends that the password be some- how correlated to the unique Electronic Serial Number (ESN) of the particular flash device. Each ESN is dif- ferent for every flash device; therefore each password should be different for every flash device. While pro- gramming in the password region, the customer may perform Password Verify operations. Once the desired password is programmed in, the customer must then set the Password Mode Locking Bit. This operation achieves two objectives: DYB PPB PPB Lock Sector State 000 Unprotected—PPB and DYB are changeable 001 Unprotected—PPB not changable, DYB is changable 010 Protected—PPB and DYB are changeable 100 110 011 Protected—PPB not changeable, DYB is changeable 101 111 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |