| поискавой системы для электроныых деталей |
|
CP5.241-S2 датащи(PDF) 23 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CP5.241-S2 датащи(HTML) 23 Page - PULS GmbH |
|
23 / 28 page ![]() CP5.241, CP5.241-C1, CP5.241-S1, CP5.241-S2, CP5.242 CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT Feb. 2018 / Rev. 0.3 DS-CP5.241-EN All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 5A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany P R E L I M I N A R Y 23. APPLICATION NOTES 23.1. PEAK CURRENT CAPABILITY The unit can deliver peak currents (up to several milliseconds) which are higher than the specified short term currents. This helps to start current demanding loads. Solenoids, contactors and pneumatic modules often have a steady state coil and a pick-up coil. The inrush current demand of the pick-up coil is several times higher than the steady-state current and usually exceeds the nominal output current (including the PowerBoost). The same situation applies when starting a capacitive load. The peak current capability also ensures the safe operation of subsequent circuit breakers of load circuits. The load branches are often individually protected with circuit breakers or fuses. In case of a short or an overload in one branch circuit, the fuse or circuit breaker need a certain amount of over-current to open in a timely manner. This avoids voltage loss in adjacent circuits. The extra current (peak current) is supplied by the power converter and the built-in large sized output capacitors of the power supply. The capacitors get discharged during such an event, which causes a voltage dip on the output. The following three examples show typical voltage dips for resistive loads: Fig. 23-1 10A peak current for 50ms , typ. (2x the nominal current) Fig. 23-2 25A peak current for 5ms , typ. (5x the nominal current) Output Voltage 24V Output Voltage 24V 23/28 10ms/DIV Output Current 0A 10A 16V Output Current 1ms/DIV 0A 25A 14V Fig. 23-3 15A peak current for 12ms , typ. (3x the nominal current) 24V 10ms/DIV Output Voltage Output Current 0A 12ms 15A 10.5V Please note: The DC-OK relay triggers when the voltage dips more than 10% for longer than 1ms. Peak current voltage dips Typically from 24V to 16V At 10A for 50ms and resistive load Typically from 24V to 16.5V At 25A for 2ms and resistive load Typically from 24V to 14V At 25A for 5ms and resistive load |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |