30 / 72 page ![]() 2001 Dec 19 30 Philips Semiconductors Product specification LCD controllers/drivers PCF2113x 9.3 Bit IM When IM = 0, the chip is in character mode. In the character mode characters and icons are driven (MUX 1 : 18). The VLCD generator, if used, produces the VLCD voltage programmed in register VA. When IM = 1, the chip is in icon mode. In the icon mode only the icons are driven (MUX 1 : 2) and the VLCD generator, if used, produces the VLCD voltage as programmed in register VB. Table 7 Normal/icon mode operation 9.4 Bit IB Icon blink control is independent of the cursor/character blink function. When IB = 0, the icon blink is disabled. Icon data is stored in CGRAM character 0 to 2 (3 × 8 × 5 = 120 bits for 120 icons). When IB = 1, the icon blink is enabled. In this case each icon is controlled by two bits. Blink consists of two half phases (corresponding to the cursor on and off phases called even and odd phases hereafter). Icon states for the even phase are stored in CGRAM characters 0 to 2 (3 × 8 × 5 = 120 bits for 120 icons). These bits also define icon state when icon blink is not used (see Table 9). Icon states for the odd phase are stored in CGRAM character 4 to 6 (another 120 bits for the 120 icons). When icon blink is disabled CGRAM characters 4 to 6 may be used as normal CGRAM characters. 9.5 Direct mode When DM = 0, the chip is not in the direct mode. Either the internal VLCD generator or an external voltage may be used to achieve VLCD. When DM = 1, the chip is in direct mode. The internal VLCD generator is turned off and the VLCD2 output is directly connected to the VLCD generator supply voltage VDD2. The direct mode can be used to reduce the current consumption when the required VLCD2 output voltage is close to the VDD2 supply voltage. This can be the case in icon mode or in Mux 1:9 (depending on LCD liquid properties). 9.6 Voltage multiplier control Bits S1 and S0 A software configurable voltage multiplier is incorporated in the VLCD generator and can be set via the ‘Set HVgen stages’ command. The voltage multiplier control can be used to reduce current consumption by disconnecting internal voltage multiplier stages, depending on the required VLCD output voltage (see Table 8). Table 8 S1 and S0 control of voltage multiplier 9.7 Screen configuration Bit L L = 0: the two halves of a split screen are connected in a standard way i.e. column 1/61, 2/62 to 60/120; default. L = 1: the two halves of a split screen are connected in a mirrored way i.e. column 1/120, 2/119 to 60/61. This allows single layer PCB or glass layout. IM MODE VLCD 0 character mode generates VA 1 icon mode generates VB S1 S0 DESCRIPTION 0 0 set VLCD generator stages to 1 (2 x voltage multiplier) 0 1 set VLCD generator stages to 2 (3 x voltage multiplier) 1 0 set VLCD generator stages to 3 (4 x voltage multiplier) 1 1 do not use Table 9 Blink effect for icons and cursor character blink PARAMETER EVEN PHASE ODD PHASE Cursor character blink block (all on) normal (display character) Icons state 1; CGRAM character 0 to 2 state 2; CGRAM character 4 to 6 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |