| поискавой системы для электроныых деталей |
|
PM2102DPD датащи(PDF) 4 Page - Sames |
|
|
|||||||||||||||||||||||||||||
PM2102DPD датащи(HTML) 4 Page - Sames |
|
4 / 16 page ![]() sames PM2102DPD 4/16 http://www.sames.co.za PRELIMINARY Table 2: Jumper options Name Connecting to VSS will allow only negative energy to be measured. Option Description J1 VSS (-) Connecting to VDD will allow only positive energy to be measured. VDD (+) Connecting to jumper J2 will allow bi-directional energy measurement. J2 Connected to J1 allows for bi-directional energy measurement. J2 J1 These are digital test pins placed immediately next to the device for convenient testing. J3 N/A These are digital test pins placed immediately next to the device for convenient testing. J4 N/A This jumper must be closed when measurement is done via a CT. The jumper connects one side of the current sense resistor to ground. J5 Closed Leave this jumper open when a shunt is used. Open Closing this jumper enables the onboard mechanical counter. J6 Closed Leave unconnected if the onboard mechanical counter is not to be used, or if a stepper motor counter is used. Open This jumper connects the VDD rail of the onboard power supply to the rest of the circuit. Leave open if an external source is to be used. J7 (Used in conjunction with J8) Open This jumper must be closed to connect the onboard power supply VDD rail to the circuit. Closed This jumper connects the VSS rail of the onboard power supply to the rest of the circuit. Leave open if an external source is to be used. J8 (Used in conjunction with J7) Open This jumper must be closed to connect the onboard power supply VDD rail to the circuit. Closed Used to select the required rated conditions. See table 3 and figure 6 for further detail on the various settings possible. J11 VDD (+) VSS Used to select the required rated conditions. See table 3 and figure 6 for further detail on the various settings possible. J12 VDD (+) VSS Used to select the required rated conditions. See table 3 and figure 6 for further detail on the various settings possible. J13 VDD (+) VSS Used to select between fast and normal pulse output mode. When connected to VSS the normal pulse output mode is selected. J14 VSS Connection to VDD selects the fast output pulse mode. VDD (+) This selects the IC manufacturers test mode for normal metering. Connect to VSS. J15 VSS This jumper selects between 220V and 110V supply networks. Leaving this jumper open (default) selects a 220V network. J16 Open Closing this jumper selects a 110V network. See power supply design when opting for the 110V setting. Closed This is a test pin connected to the VDD power supply. If opting for an external supply, the VDD rail can be connected here after J7 is removed. J17 N/A Ground connection pin. Use this pin to connect the external supply mid-rail point. J18 N/A This is a test pin connected to the VSS power supply. If opting for an external supply, the VSS rail can be connected here after J8 is removed. J19 N/A When fast mode is selected this input can be used to enable or disable the internal pulse stability circuitry for the LED output pulses. Connecting to VSS disables this circuitry. SO VSS (-) Connecting to VDD enables this circuitry. VDD (+) |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |