| поискавой системы для электроныых деталей |
|
PM2007MPPE датащи(PDF) 3 Page - Sames |
|
|
|||||||||||||||||||||||||||||
PM2007MPPE датащи(HTML) 3 Page - Sames |
|
3 / 16 page ![]() USING THE SA2007P IC The EEPROM on the SA2007AP module may be programmed in circuit with the use of a PC and the IIC interface module. The interface module includes a IIC interface, a 7 way connector cable as well as all the components needed to convert the module to a trim pot less meter. Figure 2 show how to connect the module, and the interface module to a PC. Figure 2: PM2007M/PPE mains connections as well as PC programming setup Live Neutral Load sames PM2007M/PPE 3/16 To use the PM2007M/PPE module with a SA2007P integrated circuit the following components need to be changed: n n n Replace termination resistor R16 with 3.6 resistor.* Remove Channel 2 trim-pot P1.* Remove jumpers J5, J6 and J7. * Component change is only require if the module should not contain any trim-pots. W http://www.sames.co.za |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |