Back Button PM2007MPPE Datasheet HTML 3Page - Sames PM2007MPPE Datasheet HTML 4Page - Sames PM2007MPPE Datasheet HTML 5Page - Sames PM2007MPPE Datasheet HTML 6Page - Sames PM2007MPPE Datasheet HTML 7Page - Sames PM2007MPPE Datasheet HTML 8Page - Sames PM2007MPPE Datasheet HTML 9Page - Sames PM2007MPPE Datasheet HTML 10Page - Sames PM2007MPPE Datasheet HTML 11Page - Sames Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 16 page
background image
7/16
sames
PM2007M/PPE
Figure 7: Screen capture of the SA2007P setup program
CALIBRATION AND SETUP
Software is available to setup and calibrate the SA2007P
device and is supplied with this module.
The software was written with Borland C++ Ver 3 and should
run on any PC with DOS operating system. The program was
written as clear as possible so that it can easily be modified for
specific needs.
Start the program from the DOS prompt with:
Use the cursor keys to move up and down between the
parameters listed under the “SA9607P Meter Parameters”
section. Press Enter on the parameter that needs to be
changed. The options available will be displayed. Type in the
correct option or value and press Enter again. The new setting
will be displayed.
A detailed description of the parameters listed on the screen
are described in the SA2007P datasheet. The following is a
description of the functionality of the SA2007P Meter
Parameters, displayed on the PC’s screen, figure 7.
A:\Dos\sa2007p 1 1000
NAVIGATING
V
and I
nom
max
V
and I
make up the rated conditions of the module
(SA2007P’s Kr parameter). V
is the module’s rated voltage
and Imax the module’s rated current. The PM2007M/PPE
module is designed for rated conditions of 230V/60A. The
nom
max
nom
software defaults to Vnom = 230V and Imax = 60A.
LED Constant
Counter Resolut.
Counter PW
Channel1 Err / Channel2 Err
LED Constant selects the module’s LED pulse rate (calibration
LED), which is the SA2007P’s CLED parameter. The options
available are 6400 p/kWh or 3200 p/kWh. Entering a ‘0’ will
enable the 1252 pulses/second (at rated conditions) mode for
fast calibration.
Counter resolution sets the modules counter resolution
(SA2007P’s CRES parameter). The options are 1,10 or
100p/kWh.
Counter PW set up the mechanical counter’s pulse width
(SA2007P’s CPW parameter). The available options are 71ms
and 142 ms. The PM2007M/PPE module uses an impulse
counter with a pulse width of 71ms.
The module may be calibrated by entering the percentage
error in relation to a calibrated meter or Wh-Standard. The
percentage error is calculated as follows:
Error=(Energy from module – Real energy)/Real energy x 100
http://www.sames.co.za



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com