| поискавой системы для электроныых деталей |
|
MIC280 датащи(PDF) 13 Page - Micrel Semiconductor |
|
|
|||||||||||||||||||||||||||||
MIC280 датащи(HTML) 13 Page - Micrel Semiconductor |
|
13 / 23 page ![]() November 2004 13 MIC280 MIC280 Micrel Local Temperature Result Register (TEMP0) 8-bits, read-only Local Temperature Result Register D[7] D[6] D[5] D[4] D[3] D[2] D[1] D[0] read-only read-only read-only read-only read-only read-only read-only read-only Temperature Data from ADC Bit Function Operation D[7:0] Measured temperature data for the local zone. Read only Power-up default value: 0000 0000b = 00h (0°C)** Read command byte: 0000 0000b = 00h Each LSB represents one degree centigrade. The values are in a two’s complement binary format such that 0°C is reported as 0000 0000b. See Temperature Data Format (above) for more details. **TEMP0 will contain measured temperature data after the completion of one conversion. Remote Temperature Result High-Byte Register (TEMP1h) 8-bits, read only Remote Temperature Result High-Byte Register D[7] D[6] D[5] D[4] D[3] D[2] D[1] D[0] read-only read-only read-only read-only read-only read-only read-only read-only Temperature Data from ADC Bit Function Operation D[7:0] Measured temperature data for the remote zone, most significant byte. Read only Power-up default value: 0000 0000b = 00h (0°C)** Read command byte: 0000 0001b = 01h Each LSB represents one degree centigrade. The values are in a two’s complement binary format such that 0°C is reported as 0000 0000b. See Temperature Data Format (above) for more details. TEMP1h can be read using either a Read_Byte operation or a Read_Word operation. Using Read_Byte will yield the 8-bit value in TEMP1h. The complete remote temperature result in both TEMP1h and TEMP1l may be obtained by performing a Read_Word operation on TEMP1h. The MIC280 will respond to a Read_Word with a command byte of 01h (TEMP1h) by returning the value in TEMP1h followed by the value in TEMP1l. This guarantees that the data in both registers is from the same temperature-to-digital conversion cycle. The Read_Word operation is diagramed in Figure 3. This is the only MIC280 register that supports Read_Word. **TEMP1h will contain measured temperature data after the completion of one conversion. Detailed Register Descriptions |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |