15 / 21 page ![]() AD2S1205 Rev. A | Page 14 of 20 SERIAL INTERFACE The angular position and velocity are available on the AD2S1205 in two 12-bit registers. These registers can be accessed via a 3-wire serial interface (SO, RD, and SCLK) that operates at clock rates of up to 25 MHz and is compatible with SPI and DSP interface standards. The serial interface is selected by holding the SOE pin low. Data from the position and velocity integrators are first trans- ferred to the position and velocity registers using the SAMPLE pin. The RDVEL pin selects whether data is transferred from the position or velocity register to the output register, and the CS pin must be held low to transfer data from the selected register to the output register. Finally, the RD input is used to read the data that is clocked out of the output register and is available on the serial output pin (SO). When the serial interface is selected, DB11 is used as the serial output pin (SO), DB10 is used as the serial clock input (SCLK), and Pin DB0 to Pin DB9 are placed into the high imped- ance state. The timing requirements for the read cycle are described in . Figure 8 SO Output The output shift register is 16 bits wide. Data is clocked out of the device as a 16-bit word by the serial clock input (SCLK). The timing diagram for this operation is shown in Figure 8. The 16-bit word consists of 12 bits of angular data (position or velocity, depending on RDVEL input), one RDVEL status bit, and three status bits (a parity bit, a degradation of signal bit, and a loss of tracking bit). Data is clocked out MSB first from the SO pin, beginning with DB15. DB15 through DB4 correspond to the angular information. The angular position data format is unsigned binary, with all 0s corresponding to 0° and all 1s cor- responding to 360° − l LSB. The angular velocity data format is twos complement, with the MSB representing the rotation direction. DB3 is the RDVEL status bit, with a 1 indicating position and a 0 indicating velocity. DB2 is DOS, the degradation of signal flag (refer to the section). Bit 1 is LOT, the loss of tracking flag (refer to the section). Bit 0 is PAR, the parity bit. The position and velocity data are in odd parity format, and the data readback always contains an odd number of logic highs (1s). Fault Detection Circuit Fault Detection Circuit SAMPLE Input Data is transferred from the position and velocity integrators to the position and velocity registers, respectively, after a high-to- low transition on the SAMPLE signal. This pin must be held low for at least t1 to guarantee correct latching of the data. RD should not be pulled low before this time because data will not be ready. The converter continues to operate during the read process. CS Input The device is enabled when CS is held low. RD Input The 12-bit data bus lines are normally in a high impedance state. The output buffer is enabled when CS and RD are held low. The RD input is an edge-triggered input that acts as a frame synchronization signal and an output enable. On a falling edge of the RD signal, data is transferred to the output buffer. Data is then available on the serial output pin (SO); however, it is only valid after RD is held low for t9. The serial data is clocked out of the SO pin on the rising edges of SCLK, and each data bit is available at the SO pin on the falling edge of SCLK. However, as the MSB is clocked out by the falling edge of RD, the MSB is available at the SO pin on the first falling edge of SCLK. Each subsequent bit of the data-word is shifted out on the rising edge of SCLK and is available at the SO pin on the falling edge of SCLK for the next 15 clock pulses. The high-to-low transition of RD must occur during the high time of the SCLK to avoid DB14 being shifted on the first rising edge of the SCLK, which would result in the MSB being lost. RD may rise high after the last falling edge of SCLK. If RD is held low and additional SCLKs are applied after DB0 has been read, then 0s will be clocked from the data output. When reading data continuously, wait a minimum of t5 after RD is released before reapplying it. RDVEL Input RDVEL input is used to select between the angular position register and the angular velocity register. RDVEL is held high to select the angular position register and low to select the angular velocity register. The RDVEL pin must be set (stable) at least t4 before the RD pin is pulled low. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |