17 / 25 page ![]() Rev. 1.20 17 November 25, 2015 HT9B92 Software Reset and Oscillator Mode Setting Command Thiscommandisusedtoselectthesystemoscillatorsourceandtoinitiateasoftwarereset. Function (MSB) Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 (LSB) Bit0 Note System Oscillator Setting and Software Reset C 1 1 0 1 X P1 P0 — P1 Software Reset Remark 0 No Operation (default) When a “Software Reset” is executed, the device will be reset to an initial condition. Other settings can be configured after Software reset is completed. 1 Initiate a Software Reset P0 Oscillator Mode Remark 0 Internal Oscillator (default) ● When the internal oscillator is used, the OSCIN pin must be connected to VSS or open-circuit. ● When the external clock mode is selected, the external clock is supplied on the OSCIN pin. 1 External Clock Input Mode When the software reset is executed, the device is initialized by an internal power-on reset circuit. The status of the internal circuits after initialization is as follows: ● All common outputs are set to VSS. ● All segment outputs are set to VSS. ● LCD Driver Output Waveform: A-type inversion. ● Internal oscillator source is selected. ● 1/3 bias is selected. ● LCD bias generator is off state. ● LCD Display and system oscillation are off state. ● Power save mode is set to normal current. ● Frame Frequency is set to 80Hz. ● Blinking function is switched off. Note that if the programmed command is not defined, the function will not be affected. Blinking Frequency Setting Command Thiscommanddefinestheblinkingfrequencyofthedisplaymodes. Function (MSB) Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 (LSB) Bit0 Note Blinking Frequency setting C 1 1 1 0 X P1 P0 — Note: P [1:0] Blinking Frequency Remark 00 Blinking off (default) — 01 0.5 Hz 10 1 Hz 11 2 Hz ● Power on status: Blinking function is switched off. ● If the programmed command is not defined, the function will not be affected. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |