31 / 46 page ![]() UM1539 Getting started Doc ID 023106 Rev 1 31/46 1.2.39 M41T83_SOX18 RTC alarm settings M41T83_SOX18 RTC has two alarm functions: ● Alarm one ● Alarm two a) Alarm one: 1. Set the alarm date and time using the alarm one date and time section on the RTC GUI window. 2. Check the A1IE checkbox to see the alarm status on the interrupt output pin of RTC. This is seen as a D6 LED glowing on the motherboard whenever the alarm match occurs. 3. Press the Write button to program the alarm one date and time in the RTC. 4. As the Alarm time is matched, the AF1 flag sets inside the flag status register and if A1IE is also checked, the D6 LED glows on the motherboard. This alarm can be seen in the GUI by pressing the Read Flag button, the AF1 flag glows and is cleared on a second press of read flags. 5. D6 LED shows the status of the #IRQ1 pin of the RTC. b) Alarm two: 1. Set the alarm date and time using the alarm two date and time section on the RTC GUI window. 2. Check the AL2E bit to enable the alarm two function. The A2IE bit is used to enable the alarm match status output on the #IRQ2 pin of RTC. 3. Press the Write button to program the alarm two configuration in RTC. 4. On the matching of RTC clock date and time with the alarm two date and time, the AF2 flag is set inside the flag status register and, if the A2IE bit is checked, then the alarm match status is also seen on the motherboard as the glow of D1 LED. D1 LED goes off on pressing the Read Alarm button. 5. The alarm status can be seen in the GUI by pressing the Read Flags button. Pressing read flags again clears the alarm register of RTC and its new status is shown in the GUI. 6. The Reset OF button is used to reset the OF bit in the alarm register and, correspondingly, the oscillator bit alarm is also cleared by the Reset button. 1.2.40 M41T83_SOX18 RTC watchdog configuration 1. The watchdog of RTC is enabled by configuring the multiplier and resolution settings and pressing the Write button. 2. The time period for watchdog is calculated by the resolution x multiplier value. This value is in seconds. 3. The watchdog alarm occurs when the time set in the watchdog register has lapsed. 4. The status of the watchdog alarm can be seen only by pressing the Read Flags button and, on the motherboard, this status is shown by the glow of the D6 LED. Pressing again the Read Alarm button clears the WDG flag in the alarm register of RTC and its status is shown in the GUI. On the motherboard the D6 LED goes off only by writing the watchdog register. Writing 0 in the watchdog register disables the watchdog function. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |