5 / 9 page ![]() ASF1400 Bidirectional Mass Flow Meter 2 Pins and Digital Interface The measurement values are provided as a signed floating point number together with the corresponding unit (sccm for mass flow, C for temperature). In case of an overflow, the output shows oF. G N D V D D / C S M O S I M I S O S C K R x D T x D 2.3 Serial Peripheral Interface (SPI) The in earlier versions available SPI interface is due to changes in electronic components no longer supported. Figure 6: ASF1400 pin out. 3 Configuration and Commands GND and VDD (Power Supply) The ASF1400 device accepts a set of commands through its RS-232 interface (see table 3 for valid commands; for correct settings of the RS-232 refer to Section 2.1).This allows the user to configure the ASF1400 device. Since the configuration is stored in the internal EEPROM, it is maintained after power breaks. The ASF1400 requires a voltage supply of between 7 V and 18 V. Since this voltage is internally regulated, there are no stringent requirements as far as ripple and stability are concerned. 2.1 Connector With the exception of the stop s command, all commands have to be terminated by the return key ( ↵, ASCII #10 or #13). After completion of a command, the ASF1400 returns ok and is ready to take a new instruction. Before entering a command, it may be necessary to clear the buffer by means of using ↵. You need an EDAC 395-010-520-102 connector to connect the sensor. Please check the EDAC homepage for details (www.edac.net). Alternatively the AVX 00 6338 020 000 04 0 or AVX 00 6338 020 000 04 2 connectors can be used to connect the ASP1400 as well. (See www.farnell.com, order codes 635789 or 635730). There is a trade-off between resolution and measurement time. Possible settings are listed in Table 2. Choosing 12 bit results in a measurement interval of 142 ms. With the max resolution of 15.2 bit, a new measurement is provided every 1280 ms. For faster sampling rates refer to the ASF1430 high speed mass flow meter device data sheet. 2.2 RS-232 Interface All configurations (see also Section 3) for the ASF1400 can be set using its RS-232 interface). To communicate with the ASF1400 via RS-232 the following pins are required: RxD (Receiving Data Line) Table 2: Resolution settings using the res=value command and corresponding response times TxD (Transmitting Data Line) GND (Ground) The RS-232 of the ASF1400 is configured as follows: Baudrate 9600 Data Bits 8 Stop Bits 1 Parity none Protocol none With these settings, the ASF1400 device can be connected to any PC or PDA equipped with terminal software. res= Resolution [bit] data interval [ms] 1 12.0 142 2 13.0 284 3 13.5 427 4 14.0 569 5 14.3 711 6 14.6 853 7 14.8 995 8 15.0 1138 9 15.2 1280 Table 3: Commands of the ASF1400 device. Command Output Description help ↵ commands Lists all available commands www.sensirion.com Version 2.2 5/9 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |