| поискавой системы для электроныых деталей |
|
55PC датащи(PDF) 15 Page - TE Connectivity Ltd |
|
|
|||||||||||||||||||||||||||||
55PC датащи(HTML) 15 Page - TE Connectivity Ltd |
|
15 / 18 page ![]() SPECIFICATION 55PC, ISSUE 8 Page 15 of 18 NOTE: ANY PRINTED COPY OF THIS DOCUMENT IS AN UNCONTROLLED COPY. © 2008-2015 Tyco Electronics Corporation. All rights reserved. 4.6.13 Shrinkage A 12-inch (305-mm) specimen of the finished wire shall be cut so that the insulation and conductor are flush at both ends. The specimen shall be placed in an air-circulating oven and maintained for a period of 1 hour at the temperature specified in the applicable SCD. The velocity of air past the specimen location in the oven shall be between 100 and 200 feet (30 and 61 m) per minute as determined at room temperature. At the end of the 1-hour period, the specimen shall be removed from the oven and allowed to return to room temperature. Shrinkage of the insulation shall be measured as the greatest distance which any layer of the insulation has receded from either end of the conductor; that is, the measurement obtained at the end showing the greater shrinkage shall be considered the shrinkage of the specimen. 4.6.14 Voltage Withstand (Post Environmental) The uninsulated ends of the specimen shall be attached to an electric lead. The specimen shall be immersed in a 5-percent, by weight, solution of sodium chloride in water at 20 to 25°C, except that the uninsulated ends and 1.5 inches (38 mm) of insulated wire or cable at each end of the specimen shall protrude above the surface of the solution. Immediately following specimen immersion, the voltage specified in the applicable SCD shall be applied at 60 Hz between all the conductors and shields, tied together, as applicable, and the water bath which shall be grounded. The voltage shall be gradually increased at a uniform rate from zero to the specified voltage in 0.5 minute, maintained at that voltage for a period of 5 minutes for finished wire specimens and 1 minute for finished cable specimens, and gradually reduced to zero in 0.5 minute. 4.6.15 Weight The weight of each lot of finished wire or cable shall be determined by Procedure I (4.6.15.1). Lots failing to meet the weight requirement of the applicable SCD when tested in accordance with Procedure I shall be subjected to Procedure II (4.6.15.2). All spools or reels failing to meet the requirements of the applicable SCD when tested to Procedure II shall be rejected. 4.6.15.1 Procedure I A length of wire or cable, sufficient to produce a measured weight to at least 3 significant figures, shall be weighed and converted to the weight per unit length shown on the applicable SCD. 4.6.15.2 Procedure II The net weight of the finished wire or cable on each spool or reel shall be obtained by subtracting the tare weight of the spool or reel from the gross weight of the spool or reel containing the finished wire or cable. The net weight of wire or cable on each spool or reel shall be divided by the accurately determined length of finished wire or cable on that spool or reel and the resultant figure converted to the weight per unit length shown on the applicable SCD. When wood or other moisture absorbent materials are used for spool or reel construction, weight determinations shall be made under substantially uniform conditions of relative humidity. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |