| поискавой системы для электроныых деталей |
|
55PC датащи(PDF) 7 Page - TE Connectivity Ltd |
|
|
|||||||||||||||||||||||||||||
55PC датащи(HTML) 7 Page - TE Connectivity Ltd |
|
7 / 18 page ![]() SPECIFICATION 55PC, ISSUE 8 Page 7 of 18 NOTE: ANY PRINTED COPY OF THIS DOCUMENT IS AN UNCONTROLLED COPY. © 2008-2015 Tyco Electronics Corporation. All rights reserved. 3.2.10 Removability of Insulation For AWG 10 and smaller finished wires, 0.5 inch (13 mm) of insulation shall be readily removable using conventional, hand-operated, wire strippers with properly-sized blades for the construction. The insulation slug shall not bunch, nor shall any conductor strands break during the removal process. 3.2.11 Shield Construction and Coverage The optical coverage of braided or spiral shields shall be 85 percent, minimum. Braided shields shall have an angle of 18 to 35 degrees relative to the axis of the cable. 3.2.12 Workmanship Workmanship of finished wire and cable shall be uniform and free of external, or internal, physical or cosmetic irregularities. 3.3 QUALIFICATION SPECIFIC REQUIREMENTS These characteristics, noted by the code "Q" in Table 3, are a function of the combination of materials and processes used to produce a given wire or cable construction. Following qualification, adherence to material specific and process specific requirements assures that the product will continue to meet the initial qualification specific requirements. Qualification specific requirements shall be as follows, when tested on the following constructions: Wire: 55PC0211-20 and 55PCF0211-20, as applicable Cable: 55PC1221-22 and 55PCF1221-22, as applicable Conductor plating and/or shield plating substitutions may be allowed provided the wire or cable construction is otherwise the same as specified. 3.3.1 Blocking When finished wire or cable is tested in accordance with 4.6.1, adjacent turns and layers of the wire or cable shall not block. Blocking shall be defined as a transfer of material between adjacent surfaces when they are separated. 3.3.2 Flammability When finished wire or cable is tested in accordance with 4.6.7, the burn length shall not exceed 3 inches (76 mm), the afterburn time shall not exceed 3 seconds, and there shall be no flaming of the facial tissue. 3.3.3 Insulation or Jacket Tensile Strength When finished wire or cable is tested in accordance with 4.6.9, the tensile strength of the total wire insulation (for dual-walled insulations, both layers pulled together as a unit), or the cable jacket, shall be 5000 lbf/inch 2 (34 N/mm2), minimum. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |