| поискавой системы для электроныых деталей |
|
CS10.244 датащи(PDF) 15 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CS10.244 датащи(HTML) 15 Page - PULS GmbH |
|
15 / 24 page ![]() CS10.244 C-Line 24V, 10A, SINGLE PHASE INPUT 15. PROTECTION FEATURES Output protection Electronically protected against overload, no-load and short-circuits*) Output over-voltage protection typ. 35Vdc max. 39Vdc In case of an internal power supply defect, a redundant circuit limits the maximum output voltage. The output shuts down and automatically attempts to restart. Degree of protection IP 20 EN/IEC 60529 Caution: For use in a controlled environment according to CSA 22.2 No 107.1-01. Penetration protection > 3.5mm e.g. screws, small parts Over-temperature protection yes Output shut-down with automatic restart Input transient protection MOV (Metal Oxide Varistor) Internal input fuse included not user replaceable *) In case of a protection event, audible noise may occur. 16. SAFETY FEATURES Input / output separation*) SELV IEC/EN 60950-1 PELV IEC/EN 60204-1, EN 50178, IEC 62103, IEC 60364-4-41 double or reinforced insulation Class of protection I PE (Protective Earth) connection required Isolation resistance > 5MOhm input to output, 500Vdc PE resistance < 0.1Ohm between housing and PE terminal Touch current (leakage current) typ. 0.64mA / 1.59mA 230Vac, 50Hz, TN-,TT-mains / IT-mains max. 0.85mA / 2.11mA 264Vac, 50Hz, TN-,TT-mains / IT-mains 17. DIELECTRIC STRENGTH The output voltage is floating and has no ohmic connection to the ground. Type and factory tests are conducted by the manufacturer. Field tests may be conducted in the field using the appropriate test equipment which applies the voltage with a slow ramp (2s up and 2s down). Connect all input-terminals together as well as all output poles before conducting the test. When testing, set the cut-off current settings to the value in the table below. Fig. 17-1 Dielectric strength A B C Type test 60s 2500Vac 3000Vac 500Vac Factory test 5s 2500Vac 2500Vac 500Vac Field test 5s 2000Vac 2000Vac 500Vac Cut-off current setting > 15mA > 15mA > 20mA A C L Input Output + Earth, PE - N B To fulfil the PELV requirements according to EN60204-1 § 6.4.1, we recommend that either the + pole, the – pole or any other part of the output circuit shall be connected to the protective earth system. This helps to avoid situations in which a load starts unexpectedly or can not be switched off when unnoticed earth faults occur. Jul. 2015 / Rev. 2.0 DS-CS10.244-EN All parameters are specified at 24V, 10A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 15/24 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |