| поискавой системы для электроныых деталей |
|
CS5.241 датащи(PDF) 11 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CS5.241 датащи(HTML) 11 Page - PULS GmbH |
|
11 / 25 page ![]() CS5.241, CS5.241-C1, CS5.241-S1 C-Line 24V, 5A, SINGLE PHASE INPUT 9. LIFETIME EXPECTANCY AND MTBF AC 100V AC 120V AC 230V Lifetime expectancy*) 135 000h*) 128 000h 144 000h*) at 24V, 2.5A and 40°C 283 000h*) 363 000h*) 408 000h*) at 24V, 2.5A and 25°C 52 000h 58 000h 72 000h at 24V, 5A and 40°C 146 000h*) 163 000h*) 204 000h*) at 24V, 5A and 25°C 27 000h 34 000h 42 000h at 24V, 6A and 40°C 76 000h 96 000h 120 000h*) at 24V, 6A and 25°C MTBF**) SN 29500, IEC 61709 638 000h 661 000h 869 000h at 24V, 5A and 40°C 542 000h 562 000h 739 000h at 24V, 6A and 40°C 1 077 000h 1 111 000h 1 495 000h at 24V, 5A and 25°C MTBF**) MIL HDBK 217F 552 000h 546 000h 574 000h at 24V, 5A and 40°C; Ground Benign GB40 497 000h 491 000h 517 000h at 24V, 6A and 40°C; Ground Benign GB40 788 000h 775 000h 800 000h at 24V, 5A and 25°C; Ground Bening GB25 *) The Lifetime expectancy shown in the table indicates the minimum operating hours (service life) and is determined by the lifetime expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours and is calculated according to the capacitor’s manufacturer specification. The manufacturer of the electrolytic capacitors only guarantees a maximum life of up to 15 years (131 400h). Any number exceeding this value is a calculated theoretical lifetime which can be used to compare devices. **) MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates reliability of a device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily represent the life of a product. The MTBF figure is a statistical representation of the likelihood of a device to fail. A MTBF figure of e.g. 1 000 000h means that statistically one unit will fail every 100 hours if 10 000 units are installed in the field. However, it can not be determined if the failed unit has been running for 50 000h or only for 100h. 10. FUNCTIONAL DIAGRAM Fig. 10-1 Functional diagram + + - - V OUT Input Fuse & Input Filter Output Voltage Regulator Power Converter Output Filter DC ok L N Output Over- Voltage Protection Input Rectifier & Inrush Limiter 115/230V Auto Select Jul. 2015 / Rev. 2.0 DS-CS5.241-EN All parameters are specified at 24V, 5A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 11/25 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |