| поискавой системы для электроныых деталей |
|
SSD1815 датащи(PDF) 15 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
SSD1815 датащи(HTML) 15 Page - List of Unclassifed Manufacturers |
|
15 / 35 page ![]() SOLOMON SSD1815 15 REV 1.5 03/2000 EXTENDED COMMAND TABLE Note: Patterns other than that given in Command Table and Extended Command Table are prohibited to enter to the chip as a command. Otherwise, unexpected result will occurs. Bit Pattern Read Command (D/C=0, R/W(WR)=1, E(RD)=0) Comment D7D6D5D4D3D2D1D0 (Data Read Back from the driver) Status Register Read D7=0: indicates an internal operation is completed. D7=1: indicates an internal operation is in progress. D6=0: indicates reverse segment mapping with column address D6=1: indicates normal segment mapping with column address D5=0: indicates the display is ON D5=1: indicates the display is OFF D4=0: initialization is not in progress D4=1: initialization is in progress after RES or software reset D3D2D1D0 = 1010, these 4-bit is fixed to 1010 which could be used to identify as Solomon Systech Device. Bit Pattern Command Comment 10101000 00X5X4X3X2X1X0 X5X4X3X2X1X0: Set Multiplex Ratio To select multiplex ratio N from 2 to 65 [Included Icon Line]. N = X5X4X3X2X1X0 + 2, eg. N = 111111b + 2 = 65 (POR) 10101001 X7X6X5X4X3X2X1X0 X1X0: Set Bias Ratio X4X3X2: Set TC Value X7X6X5: Modify Osc. Freq. X1X0 = 00: 1/8, 1/6 X1X0 = 01: 1/6, 1/5 X1X0 = 10: 1/9, 1/7 (POR) X1X0 = 11: Prohibited X4X3X2 = 000: -0.01%/C (TC0, POR) X4X3X2 = 010: -0.10%/C (TC2) X4X3X2 = 100: -0.18%/C (TC4) X4X3X2 = 111: -0.25%/C (TC7) X4X3X2 = 001, 011, 101, 110: Reserved Increase the value of X7X6X5 will increase the oscillator frequency and vice versa. This command is not recommended to be used. X7X6X5 = 011(POR) 1010101X0 X0: Set 1/4 Bias Ratio X0 = 0: use Normal Setting (POR) X0 = 1: fixed at 1/4 Bias 11010010 0X6X500010 X6X5: Set Total Frame Phases The On/Off of the Static Icon is given by 3 phases/1 phase overlap- ping of the M and MSTAT signals. This command set how many phases of dividing the M/MSTAT signals for each frame. The more the phases, the less the overlapping and thus the lower the effective driving voltage. X6X5 = 00: 3 phases X6X5 = 01: 5 phases X6X5 = 10: 7 phases (POR) X6X5 = 11: 16 phases 11010011 00X5X4X3X2X1X0 X5X4X3X2X1X0: Set Display Offset (for mux ratio has been set less than 64 only) After POR, X5X4X3X2X1X0 = 0 After setting mux ratio less than 64, data will be displayed at Center of matrix. See Table 1. To move display towards Row 0 by L, X5X4X3X2X1X0 = L To move display away from Row 0 by L, X5X4X3X2X1X0 = 64-L Note: max. value of L = (64 - display mux)/2 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |