165 / 170 page ![]() CS89712 DS502PP2 165 Units of Measurement General Conventions Hexadecimal numbers are presented with all letters in uppercase and a lowercase “h” appended or with a 0x at the beginning, for example, 0x14 and 03CAh. Binary numbers are enclosed in single quotation marks when in text (for example, ‘11’ designates a binary number). Numbers not indicat- ed by an “h”, 0x or quotation marks are decimal. Registers are referred to by acronym, as listed in the tables on the previous page, with bits listed in brackets MSB-to-LSB separated by a colon (:) (for example, CODR[7:0]), or LSB-to-MSB separated by a hyphen (for example, CODR[0–2]). “TBD” indicates values “to be determined,” “n/a” designates “not available”, “n/c” indicates a “no connect. pin” and “dc” means “don’t care”. Ethernet port Definitions • Act-Once bit Causes the Ethernet port to take a certain action once when the bit is set. To cause the action again, the software must rewrite a "1". • Committed Receive Frame A receive frame is "committed" after the frame has been buffered by the Ethernet port, and a re- ceive interrupt has been generated. • Committed Transmit Frame A transmit frame is "committed" after software has issued a Transmit Command, and the Ether- net port has reserved buffer space and notified the software that it is ready for transmit. • Cyclic Redundancy Check The method used to compute the 32-bit frame check sequence. • Event or Interrupt Event Refers to something that can trigger an inter- rupt. Items that are considered "Events" are re- ported in the three Event registers (RxEvent, TxEvent, or BufEvent) and in two counter- overflow bits (RxMISS and TxCOL). •Frame The portion of a packet from the DA to the FCS. This includes the Destination Address (DA), Source Address (SA), Length field, Data field, pad bits (if necessary), and Frame Check Sequence (FCS, also called CRC). "Frame da- ta" refers to all data from the DA to the FCS to be transmitted, or that has been received. • Frame Check Sequence The 32-bit field at the end of a frame that con- tains the cyclic redundancy check result. • Individual Address The specific Ethernet address assigned to a de- vice attached to the Ethernet media. Symbol Unit of Measure °C degree Celsius Hz hertz (cycle per second) kbits/s kilobits per second kbyte kilobyte (1,024 bytes) kHz kilohertz k Ω kilohm Mbps megabits (1,048,576 bits) per second Mbyte megabyte (1,048,576 bytes) MHz megahertz (1,000 kilohertz) µA microampere µFmicrofarad µWmicrowatt µs microsecond (1,000 nanoseconds) mA milliampere mW milliwatt ms millisecond (1,000 microseconds) ns nanosecond Vvolt Wwatt Table 94. Units of Measurement |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |